F. Diagnostic Charts

1. No Ice Production

Problem

Possible Cause

Remedy

[1] The icemaker will not

start.

a) Power Supply

1. Off, blown fuse, or

tripped breaker.

1. Turn on, replace, or reset.

2. Loose connection.

2. Tighten.

3. Bad contacts.

3. Check for continuity and

replace.

4. Not within

specifications.

4. Refer to nameplate and

correct.

b) Transformer (main

transformer)

1. Voltage tap switch

does not match
incoming voltage.

1. Verify incoming voltage,

move switch to proper
setting.

2. Coil winding open or

shorted.

2. Replace.

c) Water Supply

1. Water supply off or

pressure too low.

1. Check and get

recommended pressure.

d) Bin Control Thermostat 1. Tripped with bin filled

with ice.

1. Remove ice.

2. Ambient temperature

too cool.

2. Increase ambient

temperature.

3. Set too warm.

3. See "IV.C. Bin Control

Check."

4. Bulb out of position.

4. Place in position.

5. Bad contacts.

5. Check for continuity and

replace.

e) Fuse (Control Box)

1. Blown.

1. Check for short circuit and

replace.

f) Control Switch

1. "OFF" or "WASH"

position.

1. Move to "ICE" position.

2. Bad contacts.

2. Check for continuity and

replace.

g) High-Pressure Control 1. Bad contacts.

1. Check for continuity and

replace.

2. Dirty air filter or

condenser.

2. Clean.

3. Ambient or condenser

water temperature too
warm.

3. Reduce temperature.

4. Refrigerant

overcharged.

4. Recover, evacuate, and

recharge.

5. Fan not operating

(except water-cooled
model).

5. See chart 1.[7]

6. Refrigerant line or

components restricted.

6. Clean and replace drier.

7. Condenser water

pressure too low or off
(water-cooled model).

7. Check and get

recommended pressure.

Advertising