For Engine technical questions, please call 1-800-520-0882.

Horizontal Engines

6. Allow the Engine to run for several seconds. Then,

if the Choke lever is in the CHOKE position, move

the Choke Lever very slowly to its RUN position.

NOTE: Moving the Choke Lever too fast could stall the engine.

IMPORTANT: Allow the engine to run at no load for five minutes with no

load after each start-up so that the engine can stabilize.
7. Adjust the Throttle as needed.
8.

Break-in Period:
a. Breaking-in the engine will help to ensure proper equipment and engine operation.
b. The operational break-in period will last about 3 hours of use. During this period:

• Do not apply a heavy load to the equipment.
• Do not operate the engine at its maximum speed.

c. The maintenance break-in period will last about 20 hours of use. After this period:

• Change the engine oil.

Under normal operating conditions subsequent maintenance follows the schedule

explained in the MAINTENANCE AND SERVICING section.

Stopping the Engine

1. To stop the engine in an emergency,

turn the Engine Switch off.

2. Under normal conditions, use the following procedure:

a. Slide the Throttle or Speed Control

Lever to SLOW (the “turtle”).

b. Turn the Engine Switch off.
c. Close the Fuel Valve.