Test and adjustment, Specifications – Heath Zenith Motion Sensor Entryway Light SL-5610/15 User Manual

Page 3

Advertising
background image

3

598-1101-03

TEST AND ADJUSTMENT

Turn on the circuit breaker and light switch.

Avoid aiming the control at:

• Objects that change temperature rapidly, such as

heat-

ing vents or air conditioners. These heat sources
could cause false triggering.

• Areas where

pets or traffic may trigger the control.

Nearby large, light-colored objects reflecting light
may trigger the shut-off feature. Do not point other
lights at the sensor.

110°

30 ft (9.1m)

The detector is less sensitive to motion directly towards
it and more sensitive to across motion.

7ft
(2.1 m)

Maximum Range

Maximum

Coverage Angle

Rotate the sensor base left

and right to aim the sensor.
Adjust the sensor eye up
and down to obtain desired
coverage range.

Walk through the coverage

area noting where you are
when the lights turn on. Move
the sensor head up, down,
or sideways to change the
coverage area.

Set SENSITIVITY as needed.

Too much sensitivity may
increase false triggering.

Set the amount of TIME the

lights stay on after motion is de-
tected (1, 5, or 10 minutes).

In the test position shown above, the light will turn
on for 5 seconds each time motion is detected
dur-
ing both daylight and darkness.

SPECIFICATIONS

Range . . . . . . . . . . . . . . Up to 30 ft (9.1 m) [varies with

surrounding temperature].

Sensing Angle . . . . . . . . Up to 110°
Electrical Load . . . . . . . . Up to 60 Watt Maximum In-

candescent

Power Requirements . . . 120 VAC, 60 Hz
Operating Modes . . . . . . TEST, AUTO and MANUAL

OVERRIDE

Time Delay . . . . . . . . . . 1, 5, 10 minutes
Sensitivity . . . . . . . . . . . Adjustable
HeathCo LLC reserves the right to discontinue prod-
ucts and to change specifications at any time without
incurring any obligation to incorporate new features in
products previously sold.

ON-TIME

SENS

TEST 1 5 10

MIN MAX

Bottom of Sensor

Least Sensitive

Most Sensitive

Sensor

Motion

Motion

NOTE: Sensor has a 1

1

/

2

minute calibration period

before it will detect motion. When first turned
on, wait 1

1

/

2

minutes.

Aim Sensor

Down for Short

Coverage

Aim Sensor

Higher for Long

Coverage

For aiming, turn the SENSITIVITY (SENS) control

to the mid position and the ON-TIME control to the
TEST position.

Advertising