HONDA EG5000X User Manual

Page 21

Advertising
background image

19

Voltage Selector Switch

120V ONLY Position

120V/240V Position

Switch Position

Receptacle

Total Current

Available

Power Producing

Circuit

Set of

Receptacles

Available Power

The power available to each receptacle depends on the position of the
voltage selector switch.

When the voltage selector switch is in the 120V ONLY position, you
do not need to spread the load over the receptacles. You must,
however, make sure the load on any receptacle does not exceed its
available power shown in the preceding table and the total load does
not exceed 37.5 amps.

When the voltage selector switch is in the 120V/240V position, you
must balance the load. Divide the load between the two sets of
receptacles shown below. Balancing is necessary because each set of
receptacles is powered by only one power producing circuit that can
produce a maximum of 18.8 amps.

120V ONLY

120V/240V

1

2

3

4

5

1

2

3

4-5

18.8A

18.8A

1

2

1

3

5

2

4

30A at 120V

20A at 120V

20A at 120V

20A at 120V

None

18.8A at 120V

18.8A at 120V

18.8A at 120V

18.8A at 240V

08/02/05 13:47:12 31ZC2770_020

Advertising