Transporting / storage, Transporting/storage, 34 transporting/storage – HONDA EG5000X User Manual

Page 36

Advertising
background image

34

TRANSPORTING/STORAGE

Contact with a hot engine or exhaust system can cause serious burns
or fires. Let the engine cool before transporting or storing the
generator.

STORAGE TIME

RECOMMENDED SERVICE PROCEDURE TO
PREVENT HARD STARTING

When transporting the generator, turn the engine switch and the fuel
valve OFF. Keep the generator level to prevent fuel spillage. Fuel vapor
or spilled fuel may ignite.

Take care not to drop or strike the generator when transporting. Do not
place heavy objects on the generator.

Before storing the unit for an extended period:

1. Be sure the storage area is free of excessive humidity and dust.
2. Service according to the table below:

Less than 1 month
1 to 2 months

2 months to 1 year

1 year or more

Use gasoline stabilizers that are formulated to extend storage
life.
Contact your authorized Honda generator dealer for stabilizer
recommendations.

No preparation required
Fill with fresh gasoline and add gasoline
stabilizer *.
Fill with fresh gasoline and add gasoline
stabilizer *.
Drain the carburetor float bowl. (page 35 ).
Drain the fuel sediment cup. (page 31 ).
Fill with fresh gasoline and add gasoline
stabilizer *.
Drain the carburetor float bowl. (page 35 ).
Drain the fuel sediment cup. (page 31 ).
Remove the spark plug. Put a tablespoon of
engine oil into the cylinder. Turn the engine
slowly with the pull rope to distribute the oil.
Reinstall the spark plug.
Change the engine oil. (page 29 ).
After removal from storage, drain the stored
gasoline into a suitable container, and fill
with fresh gasoline before starting.

*

08/02/05 13:49:21 31ZC2770_035