C. BTU Specifi cations

MODELS: NDI30, NDI30-SP, NDI35, NDI35-SP,

NDI30-SPFK, NDI35-SPFK

LABORATORY: Underwriters Laboratories, Inc. (UL)
TYPE:
Vented Gas Fireplace Heater
STANDARD:
ANSI Z21.88-2009 CSA 2.33-2009

Vented Gas Fireplace Heaters

This product is listed to ANSI standards for “Vented Gas

Appliance Heaters” and applicable sections of “Gas Burn-

ing Heating Appliances for Manufactured Homes and

Recreational Vehicles”, and “Gas Fired Appliances for

Use at High Altitudes”.
Heatilator gas inserts are designed for installations into

solid fuel masonry or factory built fi replaces that have been

installed in accordance with the National, Provincial, State

and local building codes. Fireplaces are to be constructed

of non-combustible materials and, in the absence of local

or regional codes, meet criteria of NFPA 211. No additional

outside air source is required.

Models

(U.S. or Canada)

Maximum

Input

BTU/h

Minimum

Input

BTU/h

Orifi ce

Size

(DMS)

NDI30, NDI30-SP,

NDI30-SPFK (NG)

US

(0-2000 FT)

32,000

25,000

#35

CANADA

(2000-4500 FT)

28,800

23,500

#36

NDI35, NDI35-SP,

NDI35-SPFK (NG)

US

(0-2000 FT)

35,000

26,000

#33

CANADA

(2000-4500 FT)

33,250

25,500

#34

NDI30, NDI30-SP,

NDI30-SPFK (LP)

US

(0-2000 FT)

31,000

25,000

#51

CANADA

(2000-4500 FT)

27,500

22,500

#52

NDI35, NDI35-SP,

NDI35-SPFK (LP)

US

(0-2000 FT)

35,000

26,000

#50

CANADA

(2000-4500 FT)

31,000

25,000

#51

A. Appliance Certifi cation

NOT INTENDED FOR USE AS A PRIMARY HEAT SOURCE.

This appliance is tested and approved as either supplemen-

tal room heat or as a decorative appliance. It should not be

factored as primary heat in residential heating calculations.

D. High Altitude Installations

NOTICE: If the heating value of the gas has been reduced,

these rules do not apply. Check with your local gas utility

or authorities having jurisdiction.
When installing above 2000 feet elevation:
• In the USA: Reduce input rate 4% for each 1000 feet

above 2000 feet.

• In CANADA: Reduce input rate 10% for elevations

between 2000 feet and 4500 feet. Above 4500 feet,

consult local gas utility.

Check with your local gas utility to determine proper

orifi ce size.

NOTICE: This installation must conform with local codes.

In the absence of local codes you must comply with the

National Fuel Gas Code, ANSI Z223.1-latest edition in

the U.S.A. and the CAN/CGA B149 Installation Codes in

Canada.

1

Listing and Code Approvals

E. Non-Combustible Materials Specifi cation

Material which will not ignite and burn. Such materials are

those consisting entirely of steel, iron, brick, tile, concrete,

slate, glass or plasters, or any combination thereof.

Materials that are reported as passing

ASTM E 136,

Standard Test Method for Behavior of Materials in a

Vertical Tube Furnace at 750 ºC and UL763 shall be

considered non-combustible materials.

F. Combustible Materials Specifi cation

Materials made of or surfaced with wood, compressed pa-

per, plant fi bers, plastics, or other material that can ignite

and burn, whether fl ame proofed or not, or plastered or

unplastered shall be considered combustible materials.

G. Electrical Codes

NOTICE: This appliance must be electrically wired and

grounded in accordance with local codes or, in the absence

of local codes, with

National Electric Code ANSI/NFPA

70-latest edition or the Canadian Electric Code CSA

C22.1.
• A 120 VAC circuit for this product must be protected with

ground-fault circuit-interrupter protection, in compliance

with the applicable electrical codes, when it is installed in

locations such as in bathrooms or near sinks.

B. Glass Specifi cations

This appliance is equipped with 5 mm ceramic glass. Re-

place glass only with 5 mm ceramic glass. Please contact

your dealer for replacement glass.