19. DO NOT attempt to repair or adjust any electrical or

mechanical functions on this unit. Doing so will void

your warranty. The inside of the unit contains no user

serviceable parts. All servicing should be performed by

qualified personnel only.

20. Never place housing under water flow, or immerse in

liquids.

21. DO NOT plug in the cord with wet hands, electric shock

could result.

22. DO NOT pour water in any openings other than the

water tank.

23. If you have a warm mist humidifier, allow unit to cool

before refilling water tank or maintenance as the heater

bulb is hot.

24. To prevent damage to surfaces, do not place humidifier

under overhanging surfaces.

25. NEVER operate unit without water in the tank.
26. Do not move unit after it has been used until unit cools

completely.

27. Use both hands when carrying full tank of water.

PLEASE READ AND SAVE

THESE IMPORTANT

SAFETY INSTRUCTIONS

Consumer Safety Information

NOTE: This is an electrical appliance and requires attention

when in use.
NOTE: If moisture forms on the walls or windows of the

room, turn off the humidifier. The room already has plenty

of humidity and additional moisture may cause damage.
NOTE: DO NOT block air inlet or outlet.

Cord and Plug Installation Safety Instructions

The length of cord used on this appliance was selected to

reduce the hazards of becoming tangled in, or tripping

over a longer cord. If a longer cord is necessary an approved

extension cord may be used. The electrical rating of the

extension cord must be equal to or greater than the rating

of the humidifier (refer to the rating artwork placed on the

humidifier). Care must be taken to arrange the extension

cord so that it will not drape over the countertop or tabletop

where it can be pulled on by children or accidentally tripped

over.

HOW WARM MIST WORKS

Your Holmes

®

Warm Mist humidifier is designed to allow

the proper amount of water to flow out of the tank. Air is

drawn in through the grill openings located in the back of

the unit and mixed with steam in the misting chamber. The

warm mist is then dispersed out of the top of the misting

chamber through the outlet grill and into the room.
NOTE: A humidity level below 20% can be unhealthy and

uncomfortable. The recommended humidity level is between

40%-50%.

PRE-OPERATING INSTRUCTIONS

1. Be sure the humidifier is switched off.
2. Select a location for your humidifier, on a flat level

surface about 4 inches (10 cm) away from the wall. DO

NOT place the humidifier on a finished floor or near

furniture, which can be damaged by too much moisture

or water. Place on a moisture resistant surface.

3. Remove the tank from the main housing.
4. Bring the tank to the sink, turn upside down and twist

off the tank cap by turning counter clockwise. Fill tank

with cool, fresh tap water. DO NOT fill with warm water

as this may cause leaking. Replace the cap on tank

FIRMLY. The tank will hold 1.8 gallons of water. The

humidifier will produce up to 3 gallons of water over a

24 hour time period.

5. Make sure the safety lock is rotated completely to the

locked position. Place tank back on to the base. The

tank will immediately begin to empty into the base.

6. Plug the humidifier into a 120V electrical outlet.

P L E A S E R E A D A N D S AV E T H E S E

I M P O R TA N T S A F E T Y I N S T R U C T I O N S

F E AT U R E S - O P E R AT I O N S

When using electrical appliances, basic safety precautions

should always be followed to reduce the risk of fire, electric

shock, and injury to persons, including the following:
1. Read all instructions before using the appliance.
2. To avoid fire or shock hazard, plug the appliance

directly into a 120V AC electrical outlet.

3. Keep the cord out of heavy traffic areas. To avoid fire

hazard, NEVER put the cord under rugs or near heat

registers.

4. DO NOT place humidifier near heat sources such as stoves,

radiators, and heaters. DO locate your humidifier on an

inside wall near an electrical outlet. The humidifier should be

at least 4 inches (10 cm) away from the wall for best results.

5. NEVER place humidifier in an area where it is accessible to

children. NEVER use humidifier in a closed room, particularly

where a child may be sleeping, resting, or playing (a

closed room may result in excessive humidity).

6. WARNING: Do not attempt to refill humidifier without

first unplugging the unit from its electrical outlet.

Failure to heed this warning may cause personal

injury. Be sure to unplug the unit by pulling on the

plug and not the cord.

7. Never place anything over moisture outlet when the

unit is running.

8. NEVER drop or insert any object into any openings. DO

NOT place hands, face or body directly over or near

Moisture Outlet while unit is in operation. DO NOT

cover Moisture Outlet while the unit is operating.

9. DO NOT operate any appliance with a damaged cord or

plug, after the appliance malfunctions, or if it has been

dropped or damaged in any manner. Return appliance

to manufacturer for examination, electrical or mechanical

adjustment, or repair.

10. Use appliance only for intended household use as described

in this manual. Any other use not recommended by the

manufacturer may cause fire, electric shock, or injury to

persons. The use of attachments not recommended or sold

the manufacturer may cause hazards.

11. DO NOT use outdoors.
12. Always place humidifier on a firm, flat, level surface. A

waterproof mat or pad is recommended for use under

the humidifier. NEVER place it on a rug or carpet, or on

a finished floor that may be damaged by exposure to

water or moisture.

13. DO NOT allow the Moisture Outlet to directly face the wall.

Moisture could cause damage, particularly to wall paper.

14. Humidifier should be unplugged when not in use.
15. NEVER tilt, move, or attempt to empty unit while it is

operating. Shut off and unplug before removing the

water tank and moving the unit. If you have a warm

mist humidifier, DO NOT attempt to remove the water

tank within 15 minutes after the humidifier is turned

off and unplugged. Serious injury may result.

16. This humidifier requires daily and weekly maintenance to

operate appropriately. Refer to daily and weekly cleaning

procedures. Use only cleaners and additives recommended

by the manufacturer. Never use gasoline, glass cleaner,

furniture polish, paint thinner, or other household solvents

to clean any part of the humidifier.

17. Excessive humidity in a room can cause water condensation

on windows and some furniture. If this happens, turn

the humidifier OFF.

18. Do not use humidifier in an area where humidity level

is in excess of 50%. Use a hygrometer, available at

your local retailer or through the manufacturer to

measure the humidity.

CLEANING AND MAINTENANCE INSTRUCTIONS

The following maintenance procedures must be

routinely followed in order to ensure proper, efficient

operation of your humidifier. The unit WILL NOT

WORK CORRECTLY if it is not cleaned properly.
When the unit is in use, daily and weekly maintenance is

recommended. Regular weekly cleaning prevents scale

buildup on the heating element and tray. It also prevents

micro-organisms from growing on the tray and tank. This

ensures that maximum efficiency will be achieved.
We cannot over-emphasize how essential proper

cleaning is to the maintenance and continued use

of your unit and to the avoidance of algae or

bacteria build-up.

DAILY MAINTENANCE

Allow to cool before maintenance.

1. Before cleaning, set the control to OFF position and

unplug the unit from the electrical outlet.

2. Remove the water tank then unlock the misting chamber

by rotating the safety lock towards the front of the

unit. Lift mist chamber from the unit’s base. Now lift

the tray from the base.

3. Empty water and minerals from the tray and place in

the top rack of the dishwasher. This will remove any

sediment and dirt that has accumulated in the tray.

NOTE: It is imperative that the tray is cleaned properly. The

tray is dishwasher safe (top rack ONLY) for easy cleaning.
4. Wipe the heating element clean with a soft cloth after

it has had a chance to cool.

5. Replace misting chamber and engage safety lock. The

Electronic Thermal Control Heating element is lined

with a coating that is designed to provide the easiest

cleaning and prolong the operating efficiency of the

humidifier. DO NOT use any metal or hard objects to

clean the Heating Element. Never use detergents, gasoline,

kerosene, glass cleaner, furniture polish, paint thinner

or other household solvents to clean any part of the

humidifier.

WEEKLY MAINTENANCE

Remove scale: Allow to cool before maintenance.

1. Repeat steps 1-5 in the Daily Maintenance section.
2. Clean the tray by partially filling the tray with one 8-

oz cup of undiluted white vinegar. Let solution stand

20 minutes, cleaning all interior surfaces with a soft

brush. Dampen a cloth with undiluted white vinegar

and wipe out entire tray to remove scale.

3. Rinse with clean warm water to remove scale and the white

vinegar solution before beginning to disinfect the tank.

4. Wipe the heating element clean with a soft cloth after

it has had chance to cool.

Disinfect tank:

1. Fill tank with 1/2 teaspoon of chlorine bleach and 1/2

gallon of water.

2. Let the solution stand for 20 minutes, swishing every

few minutes. Wet all surfaces.

3. Empty the tank after 20 minutes, and rinse well with

water until the bleach smell is gone. Dry with a clean

cloth or paper towel.

4. Refill the water tank with cool water; replace the

housing and water tank. Repeat ALL Operating Instructions.

STORAGE INSTRUCTIONS

When not using your humidifier for an extended period of

time:
1. Clean, rinse and thoroughly dry the humidifier as

directed in weekly maintenance. DO NOT leave any

water in the unit when storing. Leaving water in the

unit may render the unit inoperable for the following

season.

2. Place the humidifier in the original carton and store in

a cool, dry place.

OPERATING INSTRUCTIONS

IMPORTANT:

1. Turn the Power Knob to the HIGH position. The power

light will be ON and the Reset Light will be off. It is

normal for the humidifier to take about 10 minutes to

warm up and begin to mist.

2. After the unit begins misting, set the humidifier to the

desired power setting (HIGH or LOW).

RESET PROCEDURE

NOTE: When the water tank is empty and the water in the

Heating Chamber is almost empty, the Automatic Shut Off

will activate. The RESET Light will illuminate and the unit

will not operate again until you refill the water tank and

reset the humidifier.
1. Turn the power knob to Reset.
2. Unplug the unit.
3. Remove and refill the water tank, being sure to follow

the Daily Maintenance Instructions. Replace the tank

onto the base.

4. Wait 15 minutes for the Automatic Shut-Off to reset.
5. After the 15 minutes, plug in the unit and turn the

Power Knob, to HIGH. The RESET light should now be

off (if not repeat steps 1 through 5). In about 10

minutes, the humidifier will begin to produce moisture.

If the reset light is still on at this point, and the unit does

not begin to produce moisture within a few minutes, then

repeat Steps 1-5.
IMPORTANT: If you do not plan to use the humidifier for two

or more days, make sure any residual water is drained from

the water tank and base to prevent algae or bacteria growth.

USING THE HUMIDISTAT

The Humidistat feature allows you to set and maintain the

humidity level you wish for your room to maintain. The

Humidistat setting is designed to operate between 25% and

65% relative humidity range. The recommended setting is

40-50%. Turn the knob clockwise as far as it will turn to

achieve the highest humidistat setting. In this setting, the

humidifier will run constantly. To lower your desired humidity

level, simply turn the knob counterclockwise to choose your

setting. When the humidity in the room is less than the

level you have set, the humidifier will continue to produce

moisture. Once the set humidity level has been achieved,

the unit will turn off. When the room humidity drops below

your set level, the unit will automatically begin producing

moisture again. Depending on the size of your room and

your personal comfort, you will set your humidistat at

different levels. If condensation forms on your windows or

walls, or your measured room humidity reads above 50%

by use of a hygrometer, turn off your humidifier, or lower

your Humidistat level.

F E AT U R E S - O P E R AT I O N S

C L E A N I N G / M A I N T E N A N C E

S T O R A G E I N S T R U C T I O N S

Reset

Reset

Off

Power

High

Low

Figure 1

A. Humidifier Tank

B. Carry Handle

C. Tank Cap

D. Humidifier Base

E. Safety Lock

F. Removable Tray

G. 2-Speed Humidity

Control

H. Humidistat

I. Humidifier Housing

I

B

A

G

D

H

E

F

C

THIS APPLIANCE HAS A POLARIZED PLUG (one blade is wider than the

other). To reduce the risk of electric shock, this plug is intended to fit in a

polarized outlet only one way. If the plug does not fit fully in the outlet,

reverse the plug. If it still does not fit, contact a qualified electrician to

install the proper outlet.

DO NOT ATTEMPT TO MODIFY THIS PLUG OR DEFEAT THIS

SAFETY FEATURE IN ANY WAY.