598-1156-03

ON - TIME

10 5 1 TEST

MIN

MAX

SENS

Bottom of Sensor

TEST AND ADJUSTMENT

NOTE: Sensor has a 1

1

/

2

minute warm up period

before it will detect motion. When first turned
on, wait 1

1

/

2

minutes.

Turn on the circuit breaker and light switch.

Motion

Motion

The detector is most sensitive to motion across its field
of view.

Maximum Range

Maximum

Coverage Angle

Avoid aiming the control at:

• Objects that change temperature rapidly, such as

heating vents and air conditioners. These heat
sources could cause false triggering.

• Areas where

pets or traffic may trigger the control.

Nearby large, light-colored objects reflecting light
may trigger the shut-off feature. Do not point other
lights at the sensor.

60 ft.

(18.3 m)

8 ft.

(2.4 m)

110°

Least Sensitive

Most Sensitive

Sensor

Loosen the clamp screw in the

sensor ball joint and gently
rotate the sensor.

Walk through the coverage

area noting where you are
when the lights turn on. Move
the sensor head up, down, or
sideways to change the cover-
age area.

Keep the sensor at

least 1" (2.5 cm) away from
the lamps.

Adjust the SENSITIVITY

as needed. Too much
sensitivity may increase false
triggering.

Secure the sensor head by
tightening the clamp screw.

Do not overtighten the screw.

Set the amount of TIME you want the lights to stay

on after motion is detected (1, 5, or 10 minutes).

SPECIFICATIONS

Range . . . . . . . . . . . . Up to 60 ft. (18.3 m) [varies with

surrounding temperature].

Sensing Angle . . . . . . Up to 110°
Electrical Load . . . . . . Up to 300 Watt Maximum In-

candescent [Up to 150 Watt
maximum each lamp holder.]

Power Requirements . 120 VAC, 60 Hz
Operating Modes . . . . TEST, AUTO and MANUAL

MODE

Time Delay . . . . . . . . 1, 5, 10 minutes
Range . . . . . . . . . . . . Adjustable

HeathCo LLC reserves the right to discontinue prod-
ucts and to change specifications at any time without
incurring any obligation to incorporate new features
in products previously sold.

Warning - Risk of fire. Do not aim the lamps at a
combustible surface within 3 ft. (1 m).

NOTE: Meets the ENERGY STAR

®

guidelines when used

with 120 W Max bulbs.

Turn the SENSITIVITY (SENS) control to the medium

position (halfway between MIN and MAX) and the
ON-TIME control to the TEST position.

Clamp
Screw

Ball
Joint

Aim Sensor

Down for Short

Coverage

Aim Sensor

Higher for Long

Coverage