Outdoor unit – Hitachi HSU-12RD03/R2(SDB) User Manual

Page 8

Advertising
background image

Outdoor unit

1.Installation of Outdoor Unit

3.Connection

4.Attaching Drain-Elbow

2.Connection of pipes

Install according to

To bend a pipe, give the roundness as large as possible not to crush the pipe ,and the bending radius

should be 30 to 40 mm or longer.

Connecting the pipe of gas side first makes working easier.

The connection pipe is specialized for R410A.

Use the same method on indoor unit. Loosen the screws on terminal block and insert the plugs fully into
terminal block, then tighten the screws.

If wiring is not correct, proper operation can not be carried out and controller may be damaged.

If the drain-elbow is used, please attach it as
figure. (Note: Only for heat pump unit.)

Drawing for the installation of indoor and outdoor units

Insert the cable according to terminal number in the same manner as the indoor unit.

Fix the cable with a clamp.

Half union

Flare nut

Spanner

Torque wrench

Forced fastening without careful
centering may damage the
threads and cause a leakage of
gas.

Pipe Diameter

Fastening torque

Liquid side 6.35mm(1/4")

18N.m

Gas side 9.52mm(3/8")

42N.m

Be careful that matters, such as wastes of sands, etc. shall not enter the pipe.
The standard pipe length is 5m. If it is over

5m, the function of the unit will be affected. If the pipe has

to be lengthened, the refrigerant should be charged, according to 20 g/m. But the charge of refrigerant
must be conducted by professional air conditioner engineer. Before adding additional refrigerant,
perform air purging from the refrigerant pipes and indoor unit using a vacuum pump,then charge
additional refrigerant.

CAUTION

In case the elevation A is more than 5m,
oil trap shoud be installed every 5~7m

Max. Length:

B

max

=15m

Max.Elevation: A

max

=10m

In case the pipe length B is more than

10m,

the refrigerant should be charged, according to 20 g/m.

In case A is more than 5m

A

B

Outdoor unit

Indoor unit

A

B

Outdoor unit

Indoor unit

A

B

Outdoor unit

Indoor unit

Oil trap

6

Advertising
This manual is related to the following products: