Non-combustible Sealant

After completing the framing and applying the facing

materials over the framing, a bead of non-combustible

sealant must be used to close off any gaps at the top and

sides between the fireplace hearth.

30 in. min.

12 in.

Min.

12 in.

Min.

Figure 11.7 Flush Hearth Extension

Flush Hearth Extension Framing

A raised hearth extension built flush with the fireplace

opening (Figures 11.7, 11.8) requires the fireplace to be

installed on a non-combustible surface.

Non-combustible Material

Protective Metal

Hearth Strip

30 in. Min.

Hearth Extension

Micore

Finished

Floor

Note: The bottom of the fireplace

opening is 7-5/8 in. above the bottom

of the fireplace. Finished hearth must

NOT extend above this level.

Figure 11.8 Flush Hearth Extension Side View

Non-combustible Sealant