Caution, Class a metal chimney – Hearth and Home Technologies Direct Vent Gas Appliance COLBAY-FS-B User Manual

Page 19

Advertising
background image

10/08

Page 19

Quadra-Fire • Columbia Bay • 250-5195 Rev. K

3. Class A Metal Chimney

Figure 5.21

Top Adapter

Sheet Metal Screws

Flex
Pipe

HIGH WIND
TERMINATION
CAP

SHEET METAL
SCREWS

DRILL FOUR 1/8 in.
(3mm) DIAMETER
HOLES

Figure 5.22

Figure 5.23

Figure 5.24

Step 1.
Remove existing chimney cap.

Step 2.
Measure the distance from the top of the chimney to the
bottom of the ceiling support box, add 3 in. (76mm) to this
measurement, and cut a section of 4 in. (101mm) flex pipe
to that length (the flex should be fully extended).

Step 3.
Connect the end of the flex pipe section to the underside
of the top adapter, using four sheet metal screws

(Figure

5.22).

Step 4.
Pass the flex pipe down through the center of the chimney
system, and center the top adapter on the top of the chimney
pipe. Drill four 1/8 in. (3mm) diameter holes through the
top adapter, and into the chimney top. Ensure that you are
drilling into the metal on the chimney. Twist lock the high
wind termination cap onto the top adapter

(Figures 5.23

and 5.24).

Step 5.
Pull the flex pipe down through the ceiling support box, until
it protrudes approximately 3 in. (76mm). Connect the flex
pipe to the retro connector, and attach with sheet metal
screws.

Step 6.
Push the flex pipe back up into the ceiling support box,
center the retro connector, and attach it to the support box
with sheet metal screws.

Step 7.
The connection between the appliance and the retro
connector may be completed with sections of direct vent
pipe.

TERMINATION

CAP

EXISTING

METAL CHIMNEY

SYSTEM

TOP

ADAPTOR

FLASHING

4 in. (102mm)

FLEX PIPE

RETRO

CONNECTOR

DIRECT

VENT PIPE

CAUTION

Ensure that existing chimney is functionally sound and clean.
• Have inspection done by qualified chimney sweep or

professional installer BEFORE converting to direct vent
appliance.