Fieldbus slave modules, Engineering guideline eh-150 series plc 8 – Hitachi EH-150 User Manual

Page 8

Advertising
background image

Engineering Guideline

EH-150 Series PLC

8

Fieldbus Slave Modules

EH-IOCP

EH-IOCD

Profibus-DP

DeviceNet

General

Type

Profibus-DP slave module for use with

standard I/O modules of EH-150 series

DeviceNet slave module for use with

standard I/O modules of EH-150 series

Function

Max. number of base-racks

2 (2nd rack connected via EH-IOC)

2 (2nd rack connected via EH-IOC)

Max. number of modules

16

16

Node address range

1 - 99

1 - 63

Max. number of I/O's (with
64 point I/O modules

1024

1024

Max. input and output data

208 words

208 words

In data update cycle time

5ms

5ms

9.6 kbps

1200m

-

19.2 kbps

1200m

-

45.45 kbps

1200m

-

93.75 kbps

1200m

-

125 kbps

-

500m

187.5 kbps

1000m

-

250 kbps

-

250m

500 kbps

400m

100m

1500 kbps

200m

-

3 Mbps

100m

-

6 Mbps

100m

-

12 Mbps

100m

-

Approx. 600mA

Approx. 600mA

fixed at CPU-Slot

fixed at CPU-Slot

9 pin D-sub, female

5-pole DeviceNet connector

Double shielded twisted pair cables

according to Profibus specification

DeviceNet

TM

dedicated cable

System ROM/RAM check,

watch-dog timer check

System ROM/RAM check,

watch-dog timer check

GSD-file, File name:Hita049d.gsd.
This file can either be downloaded

from the web (www.hitachi-

ds.com/sub/info/updates) or received

directly from Hitachi Europe

EDS-file, File name: Absdev.eds.

This file can either be downloaded

from the web (www.hitachi-

ds.com/sub/info/updates) or received

directly from Hitachi Europe

Profibus configurator software,

Order-Number: PBDP-M-CONF

DeviceNet configurator RSNetworx

and dedicated interface adapter

File for configuration

Configurator software

Internal current consumption (5V)
I/O assignment
External connection

External wiring

Item

Fieldbus system

Max. segment
lenght (at data
transfer rate).

Self diagnosis