Heath Zenith SL-5710 User Manual

Motion sensor light control, Operation, Model sl-5710

Advertising
background image

© 2007 HeathCo LLC

598-1120-04

Requirements

• The light control requires 120-volts AC.
• If you want to use Manual Mode, the control must be

wired through a switch.

Some codes require installation by a
qualified electrician.

• This product is intended for use with the enclosed

gasket and with a junction box marked for use in wet
locations.

Note: This product is not recommended for use where
the outside temperature is below -10° F.

Model SL-5710

Light Control

Sensor

Cover Plate

Lamp Holders

Features

• Turns on lighting when motion is detected.
• Automatically turns lighting off.
• Photocell keeps the lighting off during daylight hours.
• LED indicates motion was sensed (day or night).
• Additional energy savings with compact fluorescent

bulbs.

Motion Sensor
Light Control

Plastic Hanger

Rubber Plug

Gasket

6 Screws

(3 sizes included)

Mounting Strap

Mounting Bolt

2 Compact

Fluorescent Bulbs

2 Wire

Connectors

This package includes:

OPERATION

* resets to Auto Mode at dawn.

Note: When first turned on wait about 1

1

/

2

minutes for

the circuitry to calibrate.

MANUAL MODE

ON-TIME

10 5 1 TEST

10 5 1

TEST

ON-TIME

TEST

... back on.

AUTO

1 Second

OFF then...

Put the ON-TIME switch in the 1, 5, or
10 minute position.

Note: Although the

1 minute mode can be used, the 5 or
10 minute mode is recommended for
best operation and performance when
using compact fluorescent bulbs.

Put the ON-TIME switch on the bottom
of the sensor in the TEST position.

Manual mode only works at night
because daylight returns the sensor
to AUTO.

Flip the light switch off for one second
then back on to toggle between AUTO
and MANUAL MODE.

Manual mode works only with the
ON-TIME switch in the 1, 5, or 10
position.

Move ON-TIME Switch to

1, 5, or 10 minutes

Mode Switching Summary

Flip light switch off

for one second then

back on*

MANUAL MODE

AUTO

TEST

* If you get confused while switching modes, turn the

power off for one minute, then back on. After the cali-
bration time the control will be in the AUTO mode.

Mode:

On-Time

Works:

Day Night

Test

5 Seconds

x

x

Auto

1, 5, or 10 Min

x

Manual

Until Dawn*

x

Advertising