Harbor Freight Tools 47906 User Manual

Page 6

Advertising
background image

Page 6

For technical questions, please call 1-800-444-3353.

SKU 47906

Intake and discharge pipes must be at

5.

least 1” in diameter.
Lay an off-set line from the well to the

6.

structure the pump will be installed in.

The off-set line should slope slightly

towards the well (see Fig. 2). Systems

with longer off-set lines should use larger

diameter pipe to improve efficiency.
Install the pump on a rigid, level, dry

7.

platform. This platform must provide a

solid, level surface that is capable of

supporting the weight of the pump and

attached piping filled with water. Do

not allow water to contact the pump’s

housing.

caution: DO NOT INSERT fittings into the

Intake Hole farther than 1/2”; this can

DAMAGE the Pump, diminish Pump

functions, and/or STOP water flow.
Keep the Head, the height that the

8.

pump discharge must push water before

discharge, to a minimum. The Vertical

Well Lift, Off-set Line Length, and Head

added together must be less than Max.

Total Head to have flow at output.

Effective flow decreases to 0 GPH as

Total Head reaches its maximum.
For your protection, the power outlet

9.

used should have a Ground Fault Circuit

Interrupter (GFCI). Have it installed by

a qualified electrician. Keep power line

away from water.
The inlet and discharge lines should not

10.

be wedged or stressed in a way that puts

strain on the pump. Do not support the

pump with the inlet and discharge lines.

rEV 09d