Environment

Temperature

Operating: 0° to 40° C (32° to 104° F)
Non-operating: -25° to 70° C (-13° to 158° F)

Humidity

Operating: 10 to 85 percent non-condensing at 40°C (104°F)

Altitude

Operating: Up to 3000 meters (9842 feet)
Storage: Up to 12 kilometers (39,370 feet)

Shock

Operating: 20 g, 6 ms half-sine
Non-operating: Half sine, 33G 11ms. 3/eg Axis

Vibration

Operating: 0.5 g sine, 0.4 grms random, 5 to 500 Hz
Non-operating: 2.0 g sine, 1.1 grms random, 5 to 500 Hz

Airflow

High speed

20.8 CFM (cu. ft./min)

Low speed (65%)

15.4 CFM

Power

Maximum output

70 Watts

System power
consumption

70 Watts max, 60 Watts typical

Nominal input voltage

90- 264 VAC, Universal

Input line frequency

47 - 63 Hz

Minimum input voltage 90 VAC
Maximum input voltage 264 VAC
BTU rating (80%
efficiency)

240 BTU/hr

Inrush current

Maximum of 15 amps for period between 10-150 ms at 50° C (122° F)