SET LIGHT CONTrOLS

1. Select desired ON-TIME for the light to stay on after

motion is detected (1, 5, or 20 minutes).

2. Set D

ual

B

rite

®

control to Dusk-to-Dawn (DIM) or

Normal.

Note: Meets the ENERGY STAR

®

guidelines when

D

ual

B

rite

®

function is off and ON-TIME is 1 or 5

minutes.

3. Reinstall cover.
4.

Turn power on at the fuse or circuit breaker and
light switch.

SPECIFICaTIONS

Range ........................................ Up to 30 ft. (9,1 m). [varies with surrounding temperature]
Sensing Angle ........................... Up to 190°
Electrical Load ........................... Up to 100 Watt Maximum Halogen, 78 mm T-type
Power Requirements ................. 120 VAC, 60 Hz
Operating Modes ....................... TEST, NORMAL, and MANUAL MODE
Time Delay ................................ 1, 5, 20 minutes from last motion sensed
D

ual

B

rite

®

Feature .................... Dusk-to-Dawn

SyMPTOM

Light will not come
on.

Light comes on
in daylight.

Light comes on for
no apparent rea-
son.

POSSIBLE CauSE

1. Light switch is turned off.
2. Halogen lamp is loose or

burned out.

3. Fuse is blown or circuit breaker

is turned off.

4. Daylight turn-off is in effect (re-

check after dark).

5. Incorrect circuit wiring, if this is

a new installation.

1. Wall light may be installed in a

relatively dark location.

2. Wall light is in Test. (Set control

switch to an ON-TIME position).

1. Light control may be sensing small

animals or automobile traffic.

2. D

ual

B

rite

®

Timer is on.

SyMPTOM

L i g h t t u r n s
off too late in
Dusk-to-Dawn
setting.
Light stays on
continuously.

Light flashes
on and off.

POSSIBLE CauSE

1. Wall light may be installed in a relatively

dark location.

1. Wall light is located too close to nearby

objects that cause heat to trigger the
sensor such as an air vent, dryer vent,
or brightly-painted, heat-reflective
surface.

2. Wall light is in D

ual

B

rite

®

mode.

3. Light control is in Manual mode (Switch

to Normal).

1. Heat being reflected from other objects

may be affecting the sensor. (Move or
cover other objects to find which ones
are causing the problem)
.

2. Wall light is in the Test mode. Return

to the 1, 5, or 20 minute timer mode.

TrOuBLESHOOTING GuIDE

30 ft.

(9 m)

8 ft.

(2.4 m)

190°

Maximum Range

Maximum

Coverage Angle

Motion

Motion

Least Sensitive

Most Sensitive

Sensor

The detector is less sensitive to motion directly towards it.