FLOATED SOURCE EQUIPMENT

Source units with a 2-pin mains power cord have no means to connect the audio output ground to earth ground, so usually
the audio output ground is floated from earth ground. However, this does not insure that when installed in a system, the
audio output ground will remain floated from earth ground. The input cable to this equipment may already be connected to
earth ground earlier in the audio chain, and it will typically be carried straight through to the output. It is also possible that
the audio output ground connects to the earth ground through the chassis to an earth-grounded rack. The only way to know
for sure is to test the installed system. Use an ohmmeter to check for continuity between the earth ground socket of the
mains power receptacle and the audio output ground. If the audio output ground is not connected to earth ground, it is
floated equipment.

Consult the following diagrams for examples of recommended wiring techniques:

Shield

Chassis

Audio

Ground

XLR, 1/4" Mono Amplifier

1/4" Mono: sleeve shorts

— input to Audio Ground;

XLR: short pins 1 & 3 together

COAX OR TWISTED PAIR

FLOATED,
UNBALANCED
SOURCE

2

3

1

Shield

Chassis

Audio

Ground

XLR, 1/4" TRS Amplifier

SHIELDED TWISTED PAIR

FLOATED,
UNBALANCED
SOURCE

shield connected at both ends

1

3

2

Shield

Chassis

Audio

Ground

XLR, 1/4" TRS Amplifier

SHIELDED TWISTED PAIR

FLOATED,
BALANCED
SOURCE

shield connected at both ends

1

3

2

Shield

Float

Audio

Ground

XLR, 1/4" Mono Amplifier

1/4" Mono: sleeve shorts

— input to Audio Ground;

XLR: short pins 1 & 3 together

COAX OR TWISTED PAIR

GROUNDED,
UNBALANCED
SOURCE

2

3

1