-2-

Some local building codes may require installation by a quali-
fied electrician.

INSTALLATION

For your safety, turn off power at the fuse or circuit breaker.

Note: A “3-way” circuit controls lights from two separate switches.
If you want to use this product in a single switch circuit or if you want
to install more than one motion sensing wall switch, see

Special

Installations, page 8.

Select a 3-way circuit that controls a light or an outlet to a lamp.

Total lighting must be from

25 to 500 watts incandescent, or 60

to 400 watts fluorescent using a

rapid start ballast. Note: May

not be used to operate electronic or magnetic ballasts.

Less

wattage than the minimum may not allow the control to work
properly. The switch selected for replacement should be in a place
that can detect motion in the desired area.

For easier re-wiring later, mark the house wiring with tape

indicating where the wire had been connected.

In the following section you will install a jumper wire at one 3-way
switch and replace the other switch with the SL-6107.

*

Note: The existing 3-way switch will be referred to as the “Remote

Switch” throughout the rest of the installation manual.