Warning, Troubleshooting, Problem possible cause possible solution – Hoover WindTunnel UH70105 User Manual

Page 13

Advertising
background image

13

probleM

possible Cause

possible solution

Vacuum won’t

run

1. Power cord not firmly plugged

into outlet.

1. Plug unit in firmly.

2. Blown fuse or tripped breaker. 2. Check fuse or breaker in home. Replace

fuse/reset breaker in home.

3. Thermal Protector activated.

3. Unplug and allow vacuum to cool for 30min.

(This willl reset the thermal protector)

System Check

Indicator has

turned red

or

Vacuum won’t

pick up

or

low suction

1.Rinsable Filter and/ or Filter

made with HEPA media is dirty.

1. Clean Rinsable Filter and or Filter made

with HEPA media - Pg.9

2. Dirt Cup full and/ or clogged.

2. Empty Dirt Cup - Pg.8.

3. Broken or worn Belt.

3. Replace Belt - Pg.12.

4. Brushroll and/ or Hose

clogged.

4. Check Hose - Pg.11. Check Brushroll - Pg.10.

5. Carpet height setting is

incorrect.

5. Set Carpet Height Adjustment to appropriate

setting for carpet being cleaned - Pg.7.

dust escaping

from vacuum

1. Dirt Cup full.

1. Empty Dirt Cup - Pg. 8.

2. Dirt Cup not installed correctly. 2. Review Dirt Cup removal & replacement -

Pg. 8.

3. Hose not installed correctly.

3. Review Hose installation - Pg. 7.

4. Rinsable and/ or Filter made

with HEPA media not installed

completely.

4. Review Filter Removal and Cleaning.

Powered Hand

Tool brushroll

won’t turn

1. Too much pressure being

applied to tool.

1. Continue using tool applying light pressure.

2. Blockage.

2. Remove blockage - Pg. 11

3. Low vacuum suction.

3. Check items under “Vacuum won’t pick or

Low suction.”

Smoky/burning

smell detected

1. Belt broken or stretched.

1. Replace brushroll belt - Pg. 12.

2. Brushroll is clogged.

2. Clear/ remove debris from brushroll - Pg. 10.

5. troubleshootinG

If a minor problem occurs, it usually can be solved quite easily when the cause is found by using the

checklist below.
Any other servicing should be done by an authorized service representative.

WARNING

!

!

To reduce risk of personal injury - unplug vacuum before servicing.

Advertising