Henny Penny 592 User Manual

Page 4

Advertising
background image

Model 590/592

11. Pull excess capillary line from pot and tighten nut into
frypot

wall.

Be sure capillary bulb of high limit is positioned so it does

not interfere with carrier or get damaged when cleaning

frypot.

12. With excess capillary line pulled out, tighten smaller nut.

13. Replace inner and front panels.

14. Refi ll with shortening.

There are two fuse holders on each model of the electric fryers.
To check or change fuse, unscrew black fuse holder cap.

To avoid electrical shock or property damage, move the

power switch to OFF and disconnect main circuit

breaker, or unplug cord at wall receptacle.

Checking Procedure for Fuse Holders
CONTROL PANEL FUSES 3 Phase
Remove the control panel and pull the wires from the fuse
holder terminals. Using a multimeter or continuity light, check
across the terminals. The circuit should be closed. If not, re-
place the fuse (HP# EF02-007) or fuse holder (HP# EF02-006).

2-4

1103

2-4. HIGH TEMPERATURE
LIMIT CONTROL
(Continued)

2-5. FUSE HOLDERS

Advertising
This manual is related to the following products:

590