Quickspecs, Hp z600 workstation – Hood WORKSTATION HP Z600 User Manual

Page 18

Advertising
background image

Z600 Required Power Supply Info

Z600 Required Power Supply Info

Z600 Required Power Supply Info

Z600 Required Power Supply Info

Power Supply

Power Supply

Power Supply

Power Supply

650 watt custom power supply - (Wide Ranging Active PFC)

650 watt custom power supply - (Wide Ranging Active PFC)

650 watt custom power supply - (Wide Ranging Active PFC)

650 watt custom power supply - (Wide Ranging Active PFC)

Operating Voltage Range

Operating Voltage Range

Operating Voltage Range

Operating Voltage Range

90 - 269 VAC

Rated Voltage Range

Rated Voltage Range

Rated Voltage Range

Rated Voltage Range

100 - 240 VAC

118 VAC

Rated Line Frequency

Rated Line Frequency

Rated Line Frequency

Rated Line Frequency

50-60 Hz

400 Hz

Operating Line Frequency Range

Operating Line Frequency Range

Operating Line Frequency Range

Operating Line Frequency Range

47 - 66 Hz

393 - 407 Hz

Rated Input Current

Rated Input Current

Rated Input Current

Rated Input Current

10 A @ 110-127 VAC

6 A @ 200-240 VAC

10 A @118 VAC

Heat Dissipation (Configuration and software

Heat Dissipation (Configuration and software

Heat Dissipation (Configuration and software

Heat Dissipation (Configuration and software
dependent)

dependent)

dependent)

dependent)

Typical 1578 btu/hr (397.7 kg-cal/hr)

Maximum 2705 btu/hr (681.8 kg-cal/hr)

Power Supply Fan

Power Supply Fan

Power Supply Fan

Power Supply Fan

2x60x25 mm variable speed (sleeve-bearing)fans

Energy Star Compliant (config dependent)

Energy Star Compliant (config dependent)

Energy Star Compliant (config dependent)

Energy Star Compliant (config dependent)

YES

80 PLUS® Compliant

80 PLUS® Compliant

80 PLUS® Compliant

80 PLUS® Compliant

Yes, Bronze

FEMP Standby Power Compliant@115V (Wake-on

FEMP Standby Power Compliant@115V (Wake-on

FEMP Standby Power Compliant@115V (Wake-on

FEMP Standby Power Compliant@115V (Wake-on
LAN disabled)(<2W in S5-Power Off)

LAN disabled)(<2W in S5-Power Off)

LAN disabled)(<2W in S5-Power Off)

LAN disabled)(<2W in S5-Power Off)

YES

EuP Compliant@230V (<1 W in S5-Power Off)

EuP Compliant@230V (<1 W in S5-Power Off)

EuP Compliant@230V (<1 W in S5-Power Off)

EuP Compliant@230V (<1 W in S5-Power Off)

YES

Power Consumption in sleep mode (as defined by

Power Consumption in sleep mode (as defined by

Power Consumption in sleep mode (as defined by

Power Consumption in sleep mode (as defined by
ENERGY STAR) - Suspend to RAM (S3) (Instantly

ENERGY STAR) - Suspend to RAM (S3) (Instantly

ENERGY STAR) - Suspend to RAM (S3) (Instantly

ENERGY STAR) - Suspend to RAM (S3) (Instantly
Available PC) measured at 115V.

Available PC) measured at 115V.

Available PC) measured at 115V.

Available PC) measured at 115V.

<9W

Built-in Selft Test LED

Built-in Selft Test LED

Built-in Selft Test LED

Built-in Selft Test LED

YES

Surge Tolerant Full Ranging Power Supply

Surge Tolerant Full Ranging Power Supply

Surge Tolerant Full Ranging Power Supply

Surge Tolerant Full Ranging Power Supply
(withstands power surges up to 2000V

(withstands power surges up to 2000V

(withstands power surges up to 2000V

(withstands power surges up to 2000V

YES

QuickSpecs

HP Z600 Workstation

HP Z600 Workstation

HP Z600 Workstation

HP Z600 Workstation

System Technical Specifications

DA - 13277 North America — Version 2 — April 13, 2009

Page 18

Advertising