Connecting input power, Section 5 − operation, Controls – Hobart Welding Products HSW 25 User Manual

Page 14: 5. connecting input power, 1. controls

Advertising
background image

OM-715 Page 10

Return To Table Of Contents

4-5.

Connecting Input Power

Ref. ST-800 156

Y

Input power supply wiring
and receptacle must meet
National Electrical Code and
all other code requirements.

Operate spot welder from a sepa-
rately fused or circuit breaker pro-
tected circuit, and use correct size
input conductors.

1

Rating Label

2

Cord

3

Parallel Plug On 110 Volts AC
Models

4

Tandem Plug On 220 Volts
AC Models

Do not cut ground terminal off plug.

5

Grounded Receptacle

Connect plug to matching
grounded receptacle.

1

2

3

Or

4

5

Model

Input Conductor

Size (AWG)

Fuse/Circuit Breaker

Size In Amperes

1.5 kVA 110 Volt

2.5 kVA 220 Volt

No. 10

No. 10

30

30

SECTION 5 − OPERATION

5-1.

Controls

ST-145 104-A

1

Hand Lever

Use lever to open and close tongs.
Close the hand lever during the
welding process to compress the
material between the tips. To adjust
tong pressure, see Section 4-3.

2

Start Switch

Use switch to turn weld current On
and Off. Move switch sideways in
either direction to start weld current.
Release switch to stop weld cur-
rent.

1

2

Advertising