DEFROST SYSTEM

A. DEFROST THERMOSTAT

The defrost thermostat is factory installed on a short tube
stub extending from the coil end plate. Refer to Figure 12
and confirm that the thermostat is securely fastened in
place on the tube stub.

Figure 12

Defrost Thermostat

FEEDER TUBE

TUBE STUB

DEFROST
THERMOSTAT

COIL

B. DEFROST CONTROL BOARD

The defrost board is a time/temperature control which
includes a field-selectable time period between defrost
cycles of 30, 60, or 90 minutes (quick-connects located
at board edge, factory set at 90 minutes).

Defrost mode is identical to cooling mode except that
outdoor-fan motor stops and second-stage heat is
turned on to continue warming conditioned space.

Initially, the defrost cycle timer starts when the contactor
is energized and a 24 VAC signal is present on the T1
terminal. Then the defrost cycle begins when the defrost
thermostat is closed and the cycle timer times out (30, 60,
90 or minutes).

To initiate a forced defrost cycle, the defrost thermostat
must be closed. This can be accomplished as follows:

1.

Turn off power to outdoor unit.

2.

Disconnect outdoor fan-motor lead from OF2 on
control board (refer to Figure 13). Tape lead to
prevent grounding.

3.

Restart unit in heating mode, allowing frost to
accumulate on outdoor coil.

4.

After a few minutes in heating mode, liquid line
temperature should drop below closing point of
defrost thermostat (approximately 32

°F).

5.

Short between speed-up terminals with a
flat-bladed screwdriver (refer to Figure 13). This
reduces the timing sequence to 7, 14, or 21
seconds (30, 60, or 90 minute defrost selection,
respectively).

6.

When you hear reversing valve change position,
remove screwdriver immediately; otherwise,
control will terminate normal 10-minute defrost
cycle in approximately 2 seconds.

NOTE: Length of defrost cycle is dependent upon length
of time it takes to remove screwdriver from test pins after
reversing valve has shifted.

7.

Unit will remain in defrost for remainder of
defrost-cycle time or until defrost thermostat
reopens at approximately 65

°F coil temperature of

liquid line.

8.

Turn off power to outdoor unit and reconnect
fan-motor lead to OF2 on control board (refer to
Figure 13).

Figure 13

Defrost Control Board

R8

OF1

K1

O1

R21

C2

R6

H9C1

C US

®

R14

R13

D13

R7

C4

C10

JW2

JW1

D3

C16

C7

R28

D6

JW3

C13

R4

R1

R2

R3

R1

1

R5

R26

D1

D2

D10

A29

R9

D4

C19

C9

C1

OF2

CEBD430524-01A

5501A

P2

1

Y

T1 C C O

DFT

SPEEDUP

P1
1

J1

1

P3

1

J2

30 60 90

W1

R20

1

HK32EA001

C17

U1

1

U3

O
R

W

2

Y
C

Advertising