Functions – Harbor Freight Tools Centech 2000watt continuous power inverter 69662 User Manual

Page 7

Advertising
background image

Page 7

For technical questions, please call 1-800-444-3353.

Item 69662

• Locate battery bank in a clean, well-

ventilated area, away from ignition sources

and flammable materials. Batteries release

explosive hydrogen gas while charging.

• Charge, store, and maintain batteries

according to supplier’s instructions.

b.

+

+

+

Output

(to positive

inverter terminal)

to increase

Capacity, Connect

additional

12 v / 200* ah

lead-acid

Batteries here

(to negative

inverter terminal)

Output

12 v /

200* ah

lead- acid

Battery

12 v /

200* ah

lead- acid

Battery

12 v / 400^ ah Battery Bank example

* 200 ah batteries shown for illustration.

^ Bank Capacity = (single battery capacity) x (# of

batteries) 400 ah capacity is for two, 200 ah batteries.

Connect the batteries in parallel as

shown above. Connect all of the

positive terminals to one another.

c. Then connect all the negative

terminals to one another.

d. Connect the negative and positive output cables

to opposite ends of the bank.

Do not allow

the output cables to touch one another.

e. Test the voltages at the output cables to help

ensure that the battery bank is properly wired.

If the voltage is higher than 13 volts, then part

of the battery bank is likely connected in series

(a negative terminal of one battery attached

to a positive terminal of another) instead of in

parallel. Carefully examine the diagram and

correct the wiring before attaching to the inverter.

6. Turn the inverter’s Switch off.

7. Connect the output cables from the

battery bank to the inverter.

Functions

Figure a

115 VAC Outlets

BaCK

Power

Switch

USB

Connection

Power

Level

Indicator

Positive (+) Cable

Connection

Negative (-) Cable

Connection

Ground Connection

FROnt

Sa

Fet

Y

Ope

R

ati

O

n

m

aintenan

C

e

Setup

Advertising