CT50A, CT51A, CT53A THERMOSTATS

3

69-0265ES

THERMOSTAT OPERATION

!

On the CT51A, the system switch controls as follows:
HEAT—heating system only operates.
OFF—heating and cooling systems are disconnected.
COOL—cooling system only operates.

!

The fan switch controls as follows:
AUTO—fan on when heating or cooling system
operates.
ON—fan operates continuously.

NOTE: In the following instruction, disregard cooling

directions if not applicable to your system.

!

Turn on power to the heating/cooling system.

!

Observe system operation for at least one cycle on
both heating and cooling.

!

To observe: Place the system switch at HEAT position
and fan switch at AUTO.

!

Move the temperature sensing lever to 10

°

F (6

°

C)

above room temperature. The furnace should turn on.
A short warm-up period may be required before the
system fan turns on.

!

Place system switch at COOL position and move
temperature sensing lever 10

°

F (6

°

C) below room

temperature. The cooling equipment should turn on
and the system fan should turn on.

NOTE: Some systems have a time delay that can pre-

vent operation up to 5 minutes.

!

Turn the fan switch to ON. The system fan should turn
on, and operate continuously. The fan should continue
to operate at any system switch or thermostat setting.