Install the fan, Wiring the fan control module, Install the control module – Hearth and Home Technologies GFK4B User Manual

Page 3

Advertising
background image

Hearth & Home Technologies • GFK4B Fan Kit • 4016-095 Rev H • 11/08

3

3. Install the Fan

Position the fan all the way to the rear and center in the
appliance. Press the fan (magnets to the bottom) to the
back of the appliance. See Figure 7. Plug the fan cord
into the fan receptacle labeled “FAN” on the junction box.
See Figure 8.

BOTTOM PAN

APPLIANCE

BACK

FAN

FIREBOX

BOTTOM

Figure 7

Rotate Fan

Junction Box

Fan Assembly

Cord
Clips

Figure 8

Position the Fan

5. Wiring the Fan Control Module

Wall

Switch

RS

Valve

TP

TH

TH

TP

Fan

Control
Module

Black/White

Black Ground

Black

Red

White

Thermopile

Red

White

Figure 9

Robertshaw Wiring Diagram

4. Install the Control Module

Attach the control module to the bottom pan using the mag-
netic tape provided.

Note: Fan control timer only for use on units with junction
box pictured in Figure 9.

• Robertshaw Valve (Standing Pilot)

- Connect the black, white and red wires with 1/4 in.

female connectors from the fan control module to the
appliance junction box as shown in Figure 9.

- Connect the black ground wire with the ring terminal

to the TP screw on the valve (center).

- Remove wall switch wire connected to valve terminal

marked “TH”.

- Connect the black with white stripe wire with 3/16 in.

piggyback connector from fan control module to valve
terminal marked “TH”.

- Connect wall switch wire removed from valve terminal

“TH” to the piggyback connector on the black with white
stripe fan control module wire.

Note: Thermopile must be wired as shown in Figure 9.

Advertising