Burner and nozzle specifications

Table 1

Liquid Gas

Natural Gas

Burner

Diameter

(mm)

Thermal power

kW (p.c.s.*)

By-Pass

1/100

(mm)

Nozzle

1/100

Flow*

g/h

Nozzle

1/100

Flow*

l/h

Nomin.

Ridot.

(1)

(mm)

***

**

(mm)

Reduced Fast
(RR)

100

2,60

0,70

41

39

80

189

186

110

248

Semi Fast (S)

75

1,65

0.40

30

28

64

120

118

96

157

Auxiliary (A)

55

1,00

0,40

30

28

50

73

71

79

95

Mini WOK (MW)

110

3,50

1,30

-

57

91

254

250

138

333

Supply
Pressures

Nominal (mbar)

Minimum (mbar)

Maximum (mbar)

28-30

20
35

37
25
45

20

17

25

*

At 15°C and 1013 mbar-dry gas

**

Propane

P.C.S. = 50.37 MJ/kg.

***

Butane

P.C.S. = 49.47 MJ/kg.

Natural

P.C.S. = 37.78 MJ/m

3

(1) Only for appliances with the security device.