Motion Sensor Sensitivity

The detector is most sensitive to motion across its field of view.

Motion

Most Sensitive

Least Sensitive

Motion

Sensor

Sensor

Maximum

Coverage Angle

Maximum Range

Motion Sensor Coverage Area

70 ft.

(21 m)

8 ft.

(2.4 m)

180°

Aim Sensor down

for Short Coverage

Aim Sensor Higher

for Long Coverage

Adjusting Motion Sensor Coverage

3. Adjust RANGE Control. To increase sensitivity, turn the RANGE

control toward MAX. To decrease sensitivity, turn the RANGE
control toward MIN. Note: If the RANGE is set too high, false
triggering may result in some environments.

Note: When using test mode to check operation in the day time:
A. Set the DETECT control switch to DAY/NIGHT and
B. Set the ON-TIME control to TEST.

4. Set ON-TIME Control. Determine the amount of time you want

the connected device to stay on after motion is detected (1 or
5 minutes). Slide the ON-TIME control to the corresponding
setting.

IMPORTANT: Avoid Aiming Control At:
• Objects that change temperature rapidly, such as heating vents,

fans, and air conditioners. These air sources could cause false
triggering.

• Areas where pets or traffic may trigger the control.
• Nearby large, light colored objects reflecting light may trigger the

shut-off feature. Do not point other lights at the sensor.