Technical specifications, Quickspecs – HP ProLiant DL160 User Manual

Page 36

Advertising
background image

System Unit

System Unit

System Unit

System Unit

Dimensions

Dimensions

Dimensions

Dimensions (H x W x D)
(with bezel)

1.70 x 17.64 x 26.85 in (4.32 x 44.80 x 68.20 cm)

Weight

Weight

Weight

Weight
(approximate)

Maximum
(all hard drives, power
supplies, and processors
installed)

37.00 lb (16.78 kg)

Minimum
(one hard drive, power
supply, and processor
installed)

30.00 lb (13.69 kg)

Input Requirements

Input Requirements

Input Requirements

Input Requirements
(per power supply)

Rated Line Voltage

90 to 140 VAC
180 to 264 VAC

Rated Input Current

7.31A at 115VAC
3.6A at 230VAC

Rated Input Frequency

47 to 63 Hz

Rated Input Power

855W (at 100 VAC),
840.72W (at 200 VAC)

Power Specifications

Power Specifications

Power Specifications

Power Specifications

To review typical system power ratings use the Power Calculator which is
available via the online tool located at URL:

http://h30099.www3.hp.com/configurator/calc/Power%
20Calculator%20Catalog.xls

- Click on the system of interest. Example: DL160 G5
- Follow the instructions of the next screens.

Power Supply Output

Power Supply Output

Power Supply Output

Power Supply Output
(per power supply)

Rated Steady-State Power 653.10W (at 100 VAC),

653.08W (at 200 VAC)

System Inlet Temperature

System Inlet Temperature

System Inlet Temperature

System Inlet Temperature Operating

50° to 95° F (10° to 35° C) at sea level with an
altitude derating of 1.8°F per every 1000 ft
(1.0°C per every 305 m) above sea level to a
maximum of 10,000 ft (3050 m), no direct
sustained sunlight. Maximum rate of change is
18°F/hr (10°C/hr). The upper limit may be
limited by the type and number of options
installed.
System performance may be reduced if operating
with a fan fault or above 86°F (30°C).

Non-operating

40° to 140° F (-40° to 60° C)
Maximum rate of change is 36°F/hr (20°C/hr).

Relative Humidity

Relative Humidity

Relative Humidity

Relative Humidity
(non-condensing)

Operating

10% to 85% relative humidity (Rh), 82.4°F
(28°C) maximum wet bulb temperature, non-
condensing.

Non-operating

10% to 95% relative humidity (Rh), 101.7°F
(38.7°C) maximum wet bulb temperature, non-
condensing.

Altitude

Altitude

Altitude

Altitude

Operating

10,000 ft (3050 m). This value may be limited by
the type and number of options installed.
Maximum allowable altitude change rate is 1500
ft/min (457 m/min).

QuickSpecs

HP ProLiant DL160 Generation 5 (G5)

HP ProLiant DL160 Generation 5 (G5)

HP ProLiant DL160 Generation 5 (G5)

HP ProLiant DL160 Generation 5 (G5)

Technical Specifications

DA - 12902 Worldwide — Version 15 — August 1, 2008