Hudson Sales & Engineering Tuf-Lite 5000 Series User Manual

Page 5

Advertising
background image

Installation Manual 5000 Page 5 of 8

April 2010

After mounting, install flat washer, lock washer, and 3/8” NC
nuts. Tighten to 15 ft-lb (lubricated) or 20 ft-lb (dry).
(See Figure 7)

Note: Refer to instructions included with seal disc for further
details.

Figure 7

CHECKING TIP CLEARANCE

Rotate fan in position inside fan stack to check tip clearance
(See Figure 8)

. The recommended tip clearance is between

1” and 1 1/2 ”. Check for spots where fan blade clearance is
not within the recommended tolerance. If necessary adjust fan
stack by shimming to obtain proper clearance.

Figure 8

OPERATING INSTRUCTIONS

Start fan and check rotation. Viewed from top (discharge), fan
blades should rotate clockwise.

Check motor power consumption to be sure fan is pulling desired
load

. CAUTION: If positive pitch is set in summer to use all

available motor amps (nameplate rating), motor could be over-
loaded in winter.

Design pitch angles usually do not use all of the

available motor horsepower. This ensures that the motors will not
be overloaded at low winter temperatures.

Advertising