HP 377707-002 User Manual

Page 26

Advertising
background image

18

Operational State

Displays the general condition of the interface card. The general condition
may appear as any of the following:

unknown

normal

bootFailed

tooHot

booting

checkingBootImage

wrongBootImage

rebooting

standby

recoveryImage

A condition of unknown indicates an unsupported interface card. To
address this condition, replace the card with a supported card.
The operational state of a card must appear as normal for the current status
of the card to appear as up.
A wrongBootImage condition indicates that the active system image on
the interface card does not match the active system image on the controller.
All cards must run the same active system image as the controller card to
function.
A bootFailed condition indicates that the active system image on the card
was incompletely or incorrectly loaded. If the other interface cards come up
successfully, reset the individual card. Otherwise, reboot your entire device.
When your card overheats, the tooHot condition appears in the show card
command output. Expand the Chassis icon and click the Fans branch to
check to see if your fans failed.
The booting condition indicates that the card has not finished loading
necessary image data for internal configuration.

Boot Stage

Boot Stage appears as one of the following:

recovery

ipl

ppcboot

fpga

pic

ib

rootfs

kernel

exe

done

Table 3-1: Cards Table Fields (Continued)

Field

Description

Advertising