TEST AND ADJUSTMENT

Turn on the circuit breaker and light switch.

Motion

Motion

The detector is most sensitive to motion across its field
of view.

Loosen the clamp screw in
the sensor ball joint and gen-
tly rotate the sensor.

Walk through the coverage
area noting where you are
when the lights turn on (also,
the LED will flash several times
when motion is detected).
Move the sensor head up,
down, or sideways to change
the coverage area. Keep the
sensor at least 1" (2.5 cm)
away from the lamps.

Adjust the RANGE as needed.
RANGE set too high may
increase false triggering.

Secure the sensor head by
tightening the clamp screw. Do
not overtighten the screw.

Set the amount of TIME you want the lights to stay
on after motion is detected (1, 5, or 10 minutes).

Clamp
Screw

Ball
Joint

Aim Sensor

Down for Short

Coverage

Aim Sensor

Higher for Long

Coverage

SPECIFICATIONS

Range . . . . . . . . . . . . Up to 70 ft. (21 m) [varies with

surrounding temperature].

Sensing Angle . . . . . . Up to 150

°

Electrical Load . . . . . . Up to 300 Watt Maximum In-

candescent [Up to 150 Watt
maximum each lamp holder.]

Power Requirements . 120 VAC, 60 Hz
Operating Modes . . . . TEST, AUTO and MANUAL

MODE

Time Delay . . . . . . . . 1 , 5, 10 minutes

DESA Specialty Products™ reserves the right to dis-
continue products and to change specifications at any
time without incurring any obligation to incorporate
new features in products previously sold.

NOTE:

Sensor has a 1

1

/

2

minute warm up period

before it will detect motion. When first turned
on, wait 1

1

/

2

minutes.

RANGE

10 5 1 TEST

ON-TIME

Bottom of Sensor

Avoid aiming the control at:

• Objects that change temperature rapidly, such as

heating vents and air conditioners. These heat
sources could cause false triggering.

• Areas where pets or traffic may trigger the control.

Nearby large, light-colored objects reflecting light

may trigger the shut-off feature. Do not point other
lights at the sensor.

70 ft.

(21 m)

8 ft.

(2.4 m)

150

°

MIN

MAX

Least Sensitive

Most Sensitive

Sensor

Warning - Risk of fire. Do not aim the lamps at a
combustible surface within 3 ft. (1 m).

Maximum Range

Maximum

Coverage Angle

Turn the RANGE control to the mid position and the
ON-TIME control to the TEST position.

Advertising