Setting The Zero Point
and Balance

Before using the scale for the first time or

when the scale has been moved to another

place, you must set the zero point and

balance the scale before weighing yourself.

Zero Point

1. With nothing on the PLATFORM, slide

the UPPER and LOWER sliding weights

to ZERO.

2. To set the POINTER TIP in the middle of

the OVAL you must use the ADJUSTING

SCREW.

A. Turn the ADJUSTING SCREW

counterclockwise towards “ – “

to raise the POINTER TIP.

B.Turn the ADJUSTING SCREW

clockwise towards “ + “

to lower the POINTER TIP.

5. Use SCREW DRIVER to hook POTHOOK

into the hole of the LONG ARM CONNECTION PLATE.

6. Use ALLEN KEY to remove pre-set A SS E M B LY SCREW (located on the

bottom of the base) to release the LONG ARM CONNECTION PLAT E

into place.

7. Use ALLEN KEY to attach POLE to BASE by inserting and turning

the 4 SCREWS tightly.

8. Slide POLE COVER down.

9. Replace PLATFORM by sliding it onto BASE and push down until it

snaps into place.

Long Arm
Connection Plate

Assembly
Screw

Screws

Upper Weight

Lower Weight

Adjusting Screw

Adjusting Screw Detail

Leveling Feet

Level

Leveling Foot

Locking
Dial

Platform Top

Side

Pointer Tip

Pothook

Step1

4

5

Step2

Balance

Place the scale on a flat, firm surface. Turn the 6 LEVELING FEET until the bubble inside

the LEVEL is directly in the middle of the circle. Use LOCKING DIAL to lock LEVELING FEET

into place.

SC-650-A.qxd 10/2/06 6:10 PM Page 5