7. Make sure the extension cord is properly

wired and in good electrical condition.

Always replace a damaged extension

cord or have it repaired by a qualified

electrician before using it.

8. Protect the extension cords from sharp

objects, excessive heat, and damp or

wet areas.

RECOMMENDED MINIMUM WIRE GAUGE

FOR EXTENSION CORDS*

(120/240 VOLT)

NAMEPLATE

AMPERES

(at full load)

EXTENSION CORD

LENGTH

25’ 50’ 75’ 100’ 150’

0 – 2.0

18

18

18

18

16

2.1 – 3.4

18

18

18

16

14

3.5 – 5.0

18

18

16

14

12

5.1 – 7.0

18

16

14

12

12

7.1 – 12.0

18

14

12

10

-

12.1 – 16.0

14

12

10

-

-

16.1 – 20.0

12

10

-

-

-

TABLE A

* Based on limiting the line volt‑

age drop to five volts at 150% of

the rated amperes.

Symbology

Double Insulated

Canadian Standards Association

Underwriters Laboratories, Inc.

V~

Volts Alternating Current

A

Amperes

n0 xxxx/min.

No Load Revolutions per Minute

(RPM)

SPM

Strokes Per Minute

SPECIFICATIONS

Electrical Input

120V~ / 60Hz / 5.5A

Laser Power

2 “AAA” Batteries

(sold separately)

Speed Rating

500 to 3,000 SPM

6 settings

Stroke Length

11/16

˝ with 4 orbital settings

Blade Type

Universal - Clamp Type Holder

Saw Blades

(2x) 4

˝ x 10 TPI,

(1x) 3-1/4

˝ x 25 TPI

Bevel Adjustment

0-45° Left / 0-45° Right

Maximum Cutting Depth 2-1/2˝ @ 90° (Wood) / 1/4˝ @ 90°