Specifications, Troubleshooting guide – Heath Zenith SL-5512 User Manual

Page 5

Advertising
background image

5

595-5575-09

SPECIFICATIONS

Range . . . . . . . . . . . . Up to 70 ft. (21 m); 100 ft.

(30.5 m) with Range Boost.
[varies with surrounding
temperature]

Sensing Angle . . . . . . Up to 240°
Electrical Load . . . . . . Up to 300 Watt Maximum Incan-

descent [Up to 150 Maximum
each lamp holder].

Power Requirements . 120 VAC, 60 Hz
Operating Modes . . . . TEST, AUTO and MANUAL

MODE

Time Delay . . . . . . . . 1, 5, 20 minutes
Replacement lamp . . . T3, 150W halogen maximum

120 VAC

D

ual

B

rite

®

Timer . . . . Off, 3, 6 hours, Dusk-to-Dawn

HeathCo LLC reserves the right to discontinue prod-
ucts and to change specifications at any time without
incurring any obligation to incorporate new features in
products previously sold.

TROUBLESHOOTING GUIDE

SYMPTOM

POSSIBLE CAUSE

SOLUTION

Lights will not come
on.

1. Light switch is turned off.
2. Lamp is loose or burned out.
3. Fuse is blown or circuit breaker is turned off.
4. Daylight turn-off is in effect.
5. Incorrect circuit wiring, if this is a new installation.
6. Light control aimed in wrong direction.

1. Turn light switch on.
2. Check flood lamp and replace if burned out.
3. Replace fuse or turn circuit breaker on.
4. Recheck after dark.
5. Verify wiring is correct.
6. Re-aim light control to cover desired area.

Lights come on in day-
light.

1. Light control may be installed in a relatively dark

location.

2. Light control is in TEST.

1. The fixture is operating normally under these condi-

tions.

2. Set control switch to 1, 5, or 10 minutes.

Lights come on for no
apparent reason.

1. Light control may be sensing small animals or auto-

mobile traffic.

2. Range is set too high.
3. D

ual

B

rite

®

timer is on.

1. Re-aim light control.

2. Reduce range.
3. The fixture is operating normally under these condi-

tions.

Lights turn off too late in
Dusk-to-Dawn setting.

Light control may be installed in a relatively dark loca-
tion.

Relocate light control, or use 3 hr. or 6 hr. setting.

Lights stay on continu-
ously.

1. A lamp is positioned too close to the light control or

pointed at nearby objects that cause heat to trigger
the light control.

2. The light control may be picking up a heat source

like an air vent, dryer vent, or brightly painted, heat-
reflective surface.

3. Light control is in manual mode.

1. Reposition the flood lamp away from the light control

or nearby objects.

2. Reduce range.

3. Switch light control to AUTO.

Lights flash on and off. 1. Heat or light from the lamps may be turning the light

control on and off.

2. Heat being reflected from other objects may be turn-

ing the light control on and off.

3. Light control is in the TEST mode and warming up.

1. Reposition the flood lamp away from the light con-

trol.

2. Reposition light control.

3. Flashing is normal under these conditions.

Lights flash once, then
stay off in manual
mode.

Light control is detecting its own lights.

Reposition flood lamps to keep area below the light
control relatively dark.

Advertising