assembly and installation

The Room Sensor cable

attaches to two bare

terminals on the rear of

the circuit board. These

connections are not

polarity specific.

unpacking

The P38 is bolted (1/4 x 1" hex head bolts) to the skid to

prevent movement during shipping.
To free the stove from the skid you must remove the hold-

down bolts in the rear of the pedestal base.
removing rear cover panels

The rear cover panels are secured to the stove with three

bolts each. Two of the bolts need only be loosened, not

removed, to remove the panels. It is recommended that the

rear covers are installed after the unit is in place and the vent

pipe is installed, to prevent contact with hot or moving parts.
Firebrick

Install the single firebrick horizontally on the angle bracket

above the burnpot.
Flame guide

Install the cast iron flame guide on top of the burn pot. Make

sure that the flame guide is fully seated on the vertical sides

of the burn pot and that the back of the guide rests against

the body of the stove.
INSTALL EXHAUST VENT AT CLEARANCES SPECIFIED

BY THE MANUFACTURER. Most pellet vent pipe requires a

minimum of 3" of clearance to combustible materials although

some can be installed at 1" clearance.
Follow these instructions along with all local codes regarding

installation of this appliance.
Do

not use makeshift compromises when installing this

appliance, serious consequences may result.
With any hearth appliance, installation of smoke detectors

is recommended on every level of the home.
Possible causes of smoke detector activation:
Paint curing process - Open a window near the appliance

for the first few hours of burning.
Exhaust being drawn back inside the dwelling - Outside air

connection to the appliance is necessary.
Vent leakage - All interior seams and joints should be sealed

with silicone where appliacable. Follow vent manufacturers

instructions for proper sealing.

The room sensor (part #3-20-00906) is a small temperature

sensor on the end of a 60" wire. This sensor is installed

much like a standard wall thermostat. Use standard 18-2

thermostat wire to extend the distance to the desired location

(50' maximum). The room sensor should be installed in the

location where you want to control the temperature.

NOTE: Distances of more than 25 feet from the unit or in

another room are not recommended. The room sensor is

essential for the P38's excellent efficiency.

NOTE:

it is recommended that the room sensor be

installed, even if only installed on the rear of the unit as a

return air sensor.