Rs232 demonstration program, Rs232 – Honeywell Eclipse MS5100 Series User Manual

Page 27

Advertising
background image

23

RS232

D

EMONSTRATION

P

ROGRAM


If an RS232 scanner is not communicating with your IBM compatible PC, key in
the following BASIC program to test that the communication port and scanner are
working.

This program is for demonstration purposes only. It is only intended to prove that
cabling is correct, the COM port is working, and the scanner is working. If the bar
code data displays on the screen while using this program, it only demonstrates
that the hardware interface and scanner are working. At this point, investigate
whether the application software and the scanner configuration match.

If the application does not support RS232 scanners, a software wedge program
that will take RS232 data and place it into a keyboard buffer may be needed.
This program tells the PC to ignore RTS-CTS, Data Set Ready (DSR) and Data
Carrier Detect (DCD) signals. If the demonstration program works and yours still
does not, jumper RTS to CTS and Data Terminal Reading (DTR) to DCD and
DSR on the back of your PC.

10 CLS
20

ON ERROR GOTO 100

30 OPEN

“COM1:9600,S,7,1,CSO,DSO,CD0,LF” AS#1

35

PRINT “SCAN A FEW BAR CODES”

40

LINE INPUT #1, BARCODE$

50 PRINT

BARCODE$

60

K$ = INKEY$: IF K$ = CHR$(27) THEN GOTO 32766

70 GOTO

40

100

PRINT “ERROR NO.”; ERR ;“PRESS ANY KEY TO TERMINATE.”

110

KK$ = INKEY$: IF K$ = “”THEN GOTO 110

32766 CLOSE:

SYSTEM

32767 END

Advertising