FlashGuard 2000B Troubleshooting Guide

Page 11

Status Indicators


Control Power ON

•

Located on the control panel (top center), this indicator is illuminated whenever input

power is present and the power supply interlock switch is engaged.


High Voltage Neon Lamp

•

Located on the high voltage circuit (top) board, this lamp indicates that the high

voltage circuits are active.

•

Extreme caution should be used if the neon lamp is on.


Flashhead Alarm Status LED

•

Located on the sync/monitor (middle) board, this LED will be green when the

flashhead is operating correctly.

•

If the LED is off, the system is in alarm mode.


Sync Out LED

•

Located on the sync/monitor (middle) board, this LED blinks red to indicate that a

sync signal has been generated.

•

In a multiple flashhead system, only the sync/monitor board that is set as the master

will blink this LED.


Sync In LED

•

Located on the trigger/control (bottom) board, this LED blinks green to indicate that a

sync signal has been received from the sync/monitor board.

Tools Required

•

Flat head screwdriver

•

5/16” nutdriver to open flashhead

•

Clean gloves to use when changing flashtubes

•

Digital multimeter w/ Ohm reading and 500 VDC capacity

•

NE2 neon light, Radio Shack catalog number 272-1102, Honeywell part # 77-2342

•

Short piece of wire for jumper (Approx. #12 wire gauge)