CABLE CONNECTION 18/24 Btuh (Single Zone Only)

ELECTRICAL SPECIFICATIONS AND SYSTEM PERFORMANCE

4. Fix the connecting wire between units, with wiring fixture.

5. Attach the wiring cover.

Nominal

(1)

Sensible

HCW9000

9,500

7,030

10.9

-

-

208/230/60/1

5.0

6.1

15

HCW12000

12,000

8,760

10.6

-

-

208/230/60/1

6.2

7.6

15

HHW12000

12,000

8,760

10.4

12,500

7.2

208/230/60/1

6.2

7.6

15

HCW18000

20,000

14,200

10.7

-

-

208/230/60/1

10.2

12.5

20

HHW18000

20,000

14,200

10.3

20,000

6.9

208/230/60/1

10.2

12.5

20

HCW24000

24,000

16,800

10.3

-

-

208/230/60/1

12.1

14.8

25

HHW24000

24,000

16,800

10.0

24,000

6.8

208/230/60/1

12.0

14.8

25

(1) Indoor 80/67º F, Outdoor 95º F

(2) Indoor 70/58º F, Outdoor 47º F

Max.
Fuse

HSPF

Volts/HZ/Phase

Total

Amps

MCA

Single Zone

System

Cooling Capacity

SEER

Heating Capacity

(Btuh)

(2)

COMPLETION OF INTERCONNECTING TUBING

• Insert the wall cap into the wall, and fill the gap with sealant to prevent rain or wind.

• When using the pipe cover, fill the gap in the wall through hole in the inside.

Nominal

(5)

Sensible

AMPS

HP

RLA

LRA

AMPS

HP

HMCW18000

(1)

18,000

12,600

10.9

-

-

208/230/60/1

0.72

0.2

4.45

26

0.22

0.06

10.1

11.1

15

197

HMHW18000

(2)

17,400

11,700

10.0

17,700

6.8

208/230/60/1

0.72

0.2

4.45

26

0.22

0.06

10.1

11.1

15

197

HMCW24000

(3)

24,000

15,500

10.6

-

-

208/230/60/1

0.72

0.2

5.85

29

0.22

0.06

12.9

13.4

20

197

HMHW24000

(4)

21,000

14,100

10.0

21,250

6.8

208/230/60/1

0.72

0.2

5.85

29

0.22

0.06

12.9

13.4

20

197

(1) HMCW18000 consists of tw o HACM09DB (9,000 Btuh) air handlers and one HCCM09DB condenser.

(2) HMHW18000 consists of tw o HAHM09DB (9,000 Btuh) air handlers and one HCHM09DB condenser.

(3) HMCW24000 consists of tw o HACM12DB (12,000 Btuh) air handlers and one HCCM12DB condenser.

(4) HMHW24000 consists of tw o HAHM12DB (12,000 Btuh) air handlers and one HCHM12DB condenser.

(5) Indoor 80/67º F, Outdoor 95º F

(6) Indoor 70/58º F, Outdoor 47º F

Min

Volt

Indoor Fans

Total

Amps

MCA

HACR
BRKR

HSPF Volts/HZ/Phase

Cond Fan Mtr

Compressor

Circuits 1 & 2

Multi-Zone

System

Cooling Capacity

(Btuh)

SEER

Heating

Capacity

(Btuh)

(6)

Advertising