2.4

CONNECTING THE HOSE TO THE TURBINE


With the power switch in the OFF position, uncoil the air hose and screw it hand-tight to the turbine air
outlet.

Although the hose is designed for industrial use, it is not crushproof. Do not stand on the hose for
extended periods. For information on wire-bound crushproof hoses, please contact your local HERO
distributor or HERO directly. Also, the hose should never be used to pull the turbine or form a sharp
angle at the air outlet – this can cause premature wear of the hose, restriction of the airflow and/or
overheating of the hose.


2.5

CONNECTING THE SPRAY GUN AND TEST SPRAY


Always ensure that the gun is clean prior to being used. Any paint residue and/or particles left in the
paint cup and/or fluid tubes from previous use can spoil a finish and possibly affect the performance of
your sprayer.

Using the information provided in the Gun Accessory Kit or in Section 3.3 of this manual, determine
whether the Needle, Fluid Tip and Air Cap combination in the gun is suitable as a starting point for your
application. If not, refer to Section 3.3 of this manual for Needle, Fluid Tip and Air Cap selection, and
Section 4.4 for instructions on Changing The Needle, Fluid Tip and Air Cap.

To install the hose on the gun, pull back the ring on the Quick Disconnect Coupler to connect it to the
male tail piece on the end of the gun handle. If your unit is not equipped with a Quick Disconnect
Coupler, connect the air hose to the gun by screwing it hand-tight to the male threads at the base of the
handle of the gun.

For proper Testing Prior To Spraying, refer to Section 3.8 of this manual.