Oil level, Changing the oil filter, Transmission – HTC Z5426 User Manual

Page 52: Lubrication

Advertising
background image

English

-52

LUBRICATION

Oil Level

Check the oil level in the engine when the machine is

standing level and the engine is stopped.
Remove the dipstick, wipe it clean, and screw it back

into place.
Take the dipstick out again and read the oil level. The

oil level shall lie between the markings on the dipstick.

If the level is approaching the “ADD” mark, fill the oil to

the “FULL” mark on the dipstick. Never fill above the

“FULL” mark.
The oil is filled through the hole for the dipstick.

API class SF, SG, SH, SJ or higher must be used

Synthetic oil SAE 5W-30 or 10W30 is recommended

at all temperatures. Mineral oil SAE 5W-30, 10W30

can be used between 0 °F/-18 °C and 40 °F/+5 °C. At

temperature above 40 °F/+5 °C single grade SAE 30

must be used.
The engine holds 1.5 quarts (1.4 liters) of oil excluding

the filter; including the filter 1.6 quarts (1.5 liters).

8011-500

Remove the dipstick

8009-159

Dipstick markings

8011-739-1

Kohler oil filter

8011-739-1

Briggs & Stratton oil filter

Changing the Oil Filter

1. Drain the engine oil following the procedure

described in Engine Oil/ Change Engine Oil

section.

2. Remove the oil filter. If necessary, use a filter

remover.

3. Wipe new, clean engine oil on the seal of the new

filter.

4. Mount the filter by hand with + ¾ turn.

5. Run the engine warm, to check that there are no

leaks around the oil filter seal.

Transmission
The transmission is maintenance free and there is no

need for level checks or oil changes. If a leak occurs,

replace the unit or contact your Husqvarna dealer.