Decimal Hex

Description

-10

0F6

Invalid sweep state to set.

-11

0F5

Invalid password.

-12

0F4

Invalid input parameter in request.

-13

0F3

I/O configuration mismatch.

-14

0F2

Invalid program cannot log in.

-15

0F1

Request only valid from programmer.

-16

0F0

Request only valid in stop mode.

-17

0EF

Programmer is already attached.

-18

0EE

Could not return block sizes.

-19

0ED VMEbus error encountered.

-20

0EC

Task unable to be created.

-21

0EB

Task unable to be deleted.

-22

0EA

Not logged in to process service request.

-23

0E9

Segment selector not valid in context.

-24

0E8

No user memory is available to allocate.

-25

0E7

Configuration is not valid.

-26

0E6

CPU model number does not match.

-27

0E5

DOS file area not formatted.

-28

0E4

Segment for this selector does not exist.

-29

0E3

CPU revision number does not match.

-30

0E2

IOS could not delete configuration or bad type.

-31

0E1

No I/O configuration to read or delete.

-32

0E0

Service in process cannot login.

-33

0DF

Invalid Datagram connection address.

-34

0DE Size of Datagram connection invalid.

-35

0DD Unable to locate given connection ID.

-36

0DC Unable to find connection address.

-37

0DB Invalid segment selector in Datagram.

-38

0DA Null pointer to data in segment selector.

-39

0D9 Transfer type invalid for this selector.

-40

0D8 Point length not allowed.

-41

0D7 Invalid Datagram type specified.

-42

0D6 Datagram connection boundary exceeded.

-43

0D5 Invalid block name specified in Datagram.

-44

0D4 Mismatch of configuration checksum.

-45

0D3 User Program Module (UPM) read or write exceeded block end.

-46

0D2 Invalid write mode parameter.

-47

0D1 Packet size or total program size does not match input.

-48

0D0 One or more PLC modules configured have unsupported revision.

49

0CF

Specified device is unavailable in the system (not present).

-50

0CE

Specified device has insufficient memory to handle request.

-51

0CD Attempt was made to read a device but no data has been stored on it.

-52

0CC

Data stored on device has been corrupted and is no longer reliable.

-53

0CB

A comm or write verify error occurred during save or restore.

-54

0CA Device is write protected.