GENERAL INFORMATION

The EVENAIR

®

should be installed in branch ducts serving individual rooms, where proper air flows cannot be achieved.

The EVENAIR

®

is not designed for installation in the main air supply ducts. Locating the EVENAIR

®

near the outlet end of

a problem branch duct will provide the best performance.

The EVENAIR

®

is designed to operate in round metal or flexible type ducts.

EXAMPLE: Use the 6" KS EVENAIR

®

for 6" ducts and the 8" KS EVENAIR

®

for 8" ducts. For larger duct diameters than

indicated or for rectangular ducts, use the Model JR-1 or JR-2 EVENAIR

®

or the Model AB-1 Air Booster.

CAUTION: The EVENAIR

®

should not be installed into vertical duct pipes. Do not use this product on clothes dryer vent

pipe.

UNIT DIMENSIONS

MODEL

“A”

“B”

4” KS

4”

7-1/2”

5” KS

5”

7-1/2”

6” KS

6”

7-1/2”

8” KS

8”

7-1/2”

ELECTRICAL DATA

MODEL

VOLTS

AMPS

HZ

WATTS

RPM

THERMAL OR

IMPEDANCE

PROTECTION

MAXIMUM

TEMP

RATING*

4” KS

120AC

.29

60

19

3000

YES

155°

5” KS

120AC

.5

60

30

3000

YES

155°

6” KS

120AC

.6

60

35

3000

YES

180°

8” KS

120AC

.8

60

45

3000

YES

160°

*Do not install the EVENAIR

®

where the air temperature within the duct exceeds rated

temperature.