Connect the hot lead of the power supply to the black
wire, the neutral lead to the white wire, and the ground
wire to the green wire (See Figure 23).
A time clock controlling the filter pump should have a low-
voltage Fireman’s Switch that switches off the heater at
least 15 minutes before shutting off the pump.

FIREMAN’S SWITCH CONNECTION

NOTICE: If, while there is 120VAC connected to the
heater, you touch either 120VAC terminal with any 24VAC
wire that is connected to the control board (including the
Fireman’s Switch jumper), you will immediately destroy the
control board and void the warranty.

NOTICE: When using a timer and Fireman’s Switch, the
heater’s power supply should come from the load side of
the timer. The Fireman’s Switch completes the circuit for
the low voltage safety switches. It DOES NOT get any
power from the 115 volt power supply.
Connect the Fireman’s switch to the heater as follows:
1. Turn off power to heater at main circuit breaker panel.
2. Unbolt and remove the upper jacket halves (see Figure

3, Page 5).

3. Open control box cover (see Figure 24).
4. Remove the factory-installed jumper between the

Fireman’s Switch terminals (see Figure 25).

5. Connect the wires between the Fireman’s Switch termi-

nals on the heater and those on the time clock using
18 gauge wire with a minimum 3/64” thick insulation
rated for a temperature rise of at least 105°C. Route the
wires out through the knockout on the bottom of the
Control Box. Use a 90° conduit el and conduit run out
through the cutout on the Lower Enclosure, next to the
Junction Box (see Figure 23).

21

Wire into bottom
of Junction-box
in Flexible Conduit

Wiring Harness
to Control Box

Black to
Black

White to White

Green (Ground)

to

Green (Ground)

Bonding Wire

Bonding
Wire

Bonding Lug

View From Below
(Exterior)

View From Above
(Interior)

Cutout for
Conduit from
Fireman's Switch

PR

ES

S

TA

B

VE

NT

PIL

OT

OF

F

OFF

O

N

ON

GND

120VAC (HOT)

GROUND (GND)

NEUTRAL (NEU)

JUNCTION BOX

L1

L2

BM

FL

F1

TRANS

TRANS

F

I

R
E
M
A
N
S

S

W

I

T
C
H

Fireman's Switch
Completes the heater
24 Volt AC Control
Board Circuit.
DO NOT connect this
circuit to 115 Volt AC!

24VAC

SEC

PRIM

120VAC

Y Y

BK

BK

BK

W

W

W

W

W

G

Y

Y

JMP3

VA

L

TH

IND

GND

24V

AC

24V

AC

FS

THERMIST

OR

OPERATING CONTROL

DISABLE TOGGLE

ENABLE TOGGLE

1

CONTROL CENTER

SPA CONTROL

VERSION 1 PAD

MEMBRANE PAD

CONNECTION

TERMINAL BOARD

TRANS

TRANS

TRANS

TRANS

FUSE

FUSE

NEUTRAL

Time Clock or Remote

(Purchase Separately –

Supplies Power to

Circulator Pump)

3663 0200

24VAC

FIGURE 24: Open Control Box Cover

FIGURE 25: Fireman’s Switch Connections

FIGURE 23: Field Wiring

Advertising
This manual is related to the following products: