Furuno 1942 User Manual

Page 38

Advertising
background image

27

10. Attach the EMC core supplied as shown

below.

J806

J805

J803

J804

J802

J801

Motor

J613

J611

J1

EMC core
E04SS251512
(Above cable
clamping
plate)

Cable
entrance

IF9214

PTU-9335

MD9208

Cable
clamping
plate

Figure 6-8 How to attach EMC core

11. Fix the shield cover. Do not pinch the

cable.

12. Attach the radome cover, aligning triangle

mark on radome cover with that on ra-
dome base.

Radome cover

Radome base

Figure 6-9 How to position the radome

cover

13. Loosely fasten the radome fixing bolts.

You will tighten them after confirming
magnetron heater voltage.

Mounting (Model 1932, 1942)

Figure 6-10 Typical antenna unit mounting

locations

1. Drill four fixing bolt holes (13 millimeters

dia.), one cable entry hole (approx. 50 mil-
limeters dia.) in the mounting platform. See
the outline drawing.

6. Remove the cable clamping plate by un-

fastening four screws and removing a gas-
ket.

Shield cover

Shield cover

Pan head
screws
M4x8 7 pcs.

Pan head
screws
M4x8 7 pcs.

Pan head screws
M4x8 4 pcs.

Gasket

Cable clamping plate

Figure 6-5 Antenna unit, inside view

7. Pass the cable through the hole at the bot-

tom of the radome base.

8. Secure the cable with the cable clamping

plate and gasket. Ground the shield and
vinyl wire by one of the screws of the cable
clamping plate.

9. Connect the wire to the RF unit.

to one of the screws
of the cable clamping plate

9-pin connector:
to J801 on MD-9208

4-pin connector:
to J802 on MD-9208

13-pin connector:
to J611 on IF-9214

Figure 6-6 Signal cable, antenna unit side

J802

J801

J611

MD-9208

IF-9214

PTU-9335

Cable
entry

Figure 6-7 RF unit

Advertising