1.6 2K/4K TDI Camera Timing Diagram


4K TDI CameraLink

TM

Strobe Period

:40 nS

LVAL Set –Up Time

:20 nS

Line Period

:40.96 µS

Blanking

:1.8

µS

ExSync min Set – Up

:650 nS

ExSync min pulse Width :1.8 µS

2K TDI CameraLink

TM

Strobe Period

:40 nS

LVAL Set –Up Time

:20 nS

Line Period

:20.48 µS

Blanking

:1.8

µS

ExSync min Set – Up

:650 nS

ExSync min pulse Width :1.8 µS

Fairchild Imaging • CAM/CCD 2KCL.TDI & CAM/CCD-4KCL.TDI Line Scan Camera User’s Manual • Rev C• 11 of 30