background image

2. OPERATION

15

SAIL:

Warning signal for sailboats, tug boats and tow boats underway. One 3-second
blast, followed by one 2-second interval, one 1-second blast, one 2-second
interval and one 1-second blast. Repeated every 120 seconds.

3 s

1 s

120 s

1 s

2 s

2 s

Sailing signal

TOW:

Warning signal for vessels under tow. One 3-second blast, followed by one
2-second interval, one 1-second blast, one 2-second interval, one 1-second blast,
one 2-second interval, and one 1-second blast. Repeated every 120 seconds.

3 s

120 s

1 s

2 s

2 s

1 s

2 s

1 s

Towing signal

STOP:

Warning signal for power-driven vessel that is stationary. Two 3-second blasts,
with a 2-second interval between each blast, repeated every 120 seconds.

3 s

2 s

120 s

3 s

Stop signal