4. OPTIONAL EQUIPMENT

4-3

4.2 External

Monitor

You can display the radar image on an external monitor which accepts industrial standard
VGA input using the optional RGB kit OP03-195. Supply monitor and interconnection cable
(with HD-15P connectors of male, three rows of 15 pins) locally.

Necessary parts for external monitor

Name: RGB

kit

Type: OP03-195
Code No.: 008-553-110

Name Type Code

No.

Qty

RGB board

03P9492

008-553-680

1

Flat cable

SML2SC34-4X50BDP.5S4

000-155-457

1

Cable assy

15SDS/XHP10-005

000-144-511

1

EMI core

RFC-6

000-144-132-10

1


1. Unscrew all connector nuts at the rear of the display unit.
2. Unfasten all screws to remove the display cover.
3. Disconnect the printed circuit board 03P9415 and 03P9413.

Before disconnecting the 03P9413, disconnect J601 and J604 at the back of the board.

4. Mount the RGB board with two screws and connect the flat cable at the location shown

in the figure below.

Flat cable

RGB board

5. Remount 03P9415 and 03P9413 at their original locations and display cover.