4. OPTIONAL EQUIPMENT

4-5

4.3 Remote

Display

The FURUNO Display Unit FMD-811, MODEL1832 or GD-280/380, etc. can be connected
to this radar as a sub display. The display unit RDP-150 also can be used as a sub display.
To interconnect them, use optional cable MJ-B24LPF0008-100/200/300 (see page iv). Also,
the EMI core (option) should be attached to the remote display cable to prevent noise.

Installation materials for remote display (Type: CP03-31001、Code number: 008-556-830)

Name Type Code

no.

Qty

1 EMI

core

RFC-H13

000-146-570-10

1

2 Cable

clamp

CK-13H

000-102-947-10

1

3 Cable-tie

CV-100N

000-162-167-10

2

4 Cable-tie

CV-150N

000-162-186-10

1


1. Unscrew all connector nuts at the rear of the main display unit.
2. Unfasten all screws to remove the display cover.
3. Pass the signal cable from the “OPTION” port at the rear of the display unit through the

hole shown in the figure below and then connect it to the SPU board.

4. Fix the shield wire with a screw used to fixed the SPU board.
5. Attach the EMI core RFC-H13 on the signal cable.
6. Attach cable clamp and fix the cable as shown below.

90 mm

EMI core
RFC-H13

Attach cable-tie approx. 90 mm from the end of
cable and attach EMI core.

Remote display cable

Fix the EMI core with cable-tie CV-100.