Gas cooktop installation instructions, Lp/propane gas conversion – FRIGIDAIRE 318201452 User Manual

Page 7

Advertising
background image

GAS COOKTOP INSTALLATION INSTRUCTIONS

7

5. LP/Propane Gas Conversion

A. Pressure Regulator Conversion

IMPORTANT: Except for Puerto Rico 30" model all
cooktops are shipped from the factory set for use with
Natural gas. Please verify the serial plate.

Note: • Do not remove the Pressure Regulator.

• If in doubt about the pressure at the manifold,

use a manometer. the inlet pressure on the
regulator must be at least 1" W.C. higher
than the outlet pressure. inlet pressure on the
regulator must never exceed 14" W.C.

1. Convert the Pressure Regulator from Natural
Gas to LP Gas (see figure 9)

A. Remove the cap from the pressure regulator.
B. Remove the plunger.
C. turn the plunger upside down with the

enlarge end DOWN.

D. Replace the plunger inside the regulator. the

letters LP or 10" W.C. should be visible on the
exposed end of the plunger.

E. Replace the cap on the pressure regulator.

2. Convert the Pressure Regulator from LP Gas
to NATURAL Gas (see figure 10)

B. Burner Valves Conversion

(see figure 11 and 12)

Figure 9

LP Gas

A. Remove the cap from the pressure regulator.
B. Remove the plunger.
C. turn the plunger upside down with the

enlarge end UP.

D. Replace the plunger inside the regulator. the

letters NAt or 4" W.C. should be visible on
the exposed end of the plunger.

E. Replace the cap on the pressure regulator.

Cap

Plunger - Enlarged
end DOWN for LP
gas

Figure 10

Natural Gas

Cap

Plunger - Enlarged
end UP for Natural
gas

1. Remove valve knobs, top grates, burner pans

and lift cooktop to gain access to valves. Locate
valve hoods (orifices) on back side of valves.

2a. To convert burner valves from Natural Gas

to LP Gas, turn valve hoods (orifices) down until
snug against the mixer pin (approximately 2 ½
turns). Do not overtighten.

2b. To convert burner valves from LP Gas to

Natural Gas, turn valve hoods (orifices) up until
it is away from the mixer pin (approximately 2 ½
turns).

3. Apply gas to the burner and adjust pilots and air

shutter on burner venturi tube to proper flame
(refer to pictures in "Burner Flame Adjustment"
section for comparison).

Figure 12

Hood

Pin

Natural gas

LP gas

Figure 11

Advertising
This manual is related to the following products: